Role of mechanical factors in the evaluation of pedicle screw type spinal fixation devices.

نویسندگان

  • V K Goel
  • N A Ebraheim
  • A Biyani
  • S Rengachary
  • A Faizan
چکیده

Prior to implantation, spinal implants are subjected to rigorous testing to ensure safety and efficacy. A full battery of tests for the devices may include many steps ranging from biocompatibility tests to in vivo animal studies. This paper describes some of the essential tests from a mechanical engineering perspective (e.g., motion, load sharing, bench type tests, and finite element model analyses). These protocols reflect the research experience of the past decade or so.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شکست وسایل تثبیت ستون فقرات

This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws.

To compare the mechanical effectiveness of a new conical screw design with a conventional cylindrical screw design, the screw insertion time, torque, and pull-out strength of single-pedicle screw and triangulated-pedicle screw constructs of each type of screw were compared in human cadaveric vertebral bodies. The time required to insert the conical screws was less than that required for cylindr...

متن کامل

Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing

The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to opti...

متن کامل

Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis

OBJECTIVE To compare the von Mises stresses of the internal fixation devices among different short segment pedicle screw fixation techniques to treat thoracic 12 vertebral fractures, especially the mono-segment pedicle screw fixation and intermediate unilateral pedicle screw fixation techniques. METHODS Finite element methods were utilised to investigate the biomechanical comparison of the fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurology India

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2005