Fast Field Inhomogeneity and Concomitant Gradient Field Correction in Spiral Cardiac Imaging
نویسندگان
چکیده
Introduction: Cardiac imaging, for both real-time and triggered imaging, requires a high data acquisition rate. Spiral trajectories achieve this rate; however, their advantages are shadowed by off-resonance blurring and distortion effects. Current techniques to correct for this image degradation do not easily or quickly account for the different effects specifically field inhomogeneities and concomitant gradient fields [1-3]. We present two fast and accurate algorithms to correct for both of these effects. Speed is demonstrated in a real-time study, and accuracy is shown in a high-resolution study.
منابع مشابه
Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.
Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of co...
متن کاملFast Concomitant Gradient Field Correction for Spiral Scans
Introduction: A major drawback to non-Cartesian imaging is the off-resonance blurring effects. Common linear techniques that remove the distortion effects are not sufficient, because the high order concomitant gradient fields are nontrivial for low fields and for scans that are more than 5 cm off isocenter [1]. Previous correction algorithms either are slow or do not take into account the known...
متن کاملFast gradient-echo chemical-shift imaging.
A fast chemical-shift imaging using the gradient-echo technique is proposed for the separation of the water and fat in human in vivo imaging. This technique also incorporates magnetic field inhomogeneity correction in the fast chemical-shift imaging. Experimental results of the proposed imaging technique demonstrate that the method would be useful for quick in vivo water-fat separation imaging ...
متن کاملFast automatic linear off-resonance correction method for spiral imaging.
Field inhomogeneity and susceptibility variations, coupled with a long readout, can result in image blurring in spiral imaging. Many correction methods based on a priori off-resonance information, such as an acquired field map, have been proposed in the literature. Automatic off-resonance correction methods are alternative approaches that estimate a field map from the image data themselves. In ...
متن کاملConcomitant gradient field effects in spiral scans.
Maxwell's equations imply that imaging gradients are accompanied by higher order spatially varying fields (concomitant fields) that can cause artifacts in MR imaging. The lowest order concomitant fields depend quadratically on the imaging gradient amplitude and inversely on the static field strength. Time-varying concomitant fields that accompany the readout gradients of spiral scans cause unwa...