Weighted summation of oxygen-15-water PET data to increase signal-to-noise ratio for activation studies.

نویسندگان

  • J L Andersson
  • H Schneider
چکیده

UNLABELLED Data with the highest possible signal-to-noise (S/N) ratios are desirable when performing nonquantitative perturbation studies with PET and 15O-water. To achieve this, protocols have been suggested in which the stimulus is switched off before the washout phase. An alternative strategy is suggested for cases in which the stimulus is not easily discontinued. METHODS For a given subject, a theoretical signal curve is created by simulating tissue time-activity curves for baseline and activated states and their subtraction. The curve is created from a typical arterial curve, and values for delay and flow are estimated for that subject. When summing the activity data before image reconstruction, the values from the signal curve are used as weights. Thus, data with high information content regarding changes in blood flow are given a large weight, and data with less information are given a smaller weight. The method is examined by simulations, and the results are validated by application to data from 10 individuals from an activation study. RESULTS Simulations show that the S/N ratio peaks for a given summation time and then decline for longer times when performing a straight summation of data. This time is not constant and varies both with the whole brain flow level and the magnitude of the activation. When using weighted summation on the other hand, the S/N ratio approaches asymptotically its optimal value. The optimal S/N value for weighted summation is 5%-10% higher than the peak value obtained with straight summation. The results are confirmed by the experimental data, indicating a shift in optimal summation time from 60-100 sec and an increase by 6% in the S/N ratio for weighted compared to straight summation. CONCLUSION The method presented in this paper offers a way to significantly increase the S/N ratio in 15O-water perturbation studies without increasing invasiveness or complicating the experimental protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Analysis of Hyperspectral Imagery for Oil Spill Detection Using SAM Unmixing Algorithm Techniques

Oil spill is one of major marine environmental challenges. The main impacts of this phenomenon are preventing light transmission into the deep water and oxygen absorption, which can disturb the photosynthesis process of water plants. In this research, we utilize SpecTIR airborne sensor data to extract and classify oils spill for the Gulf of Mexico Deepwater Horizon (DWH) happened in 2010. For t...

متن کامل

Using a novel method for random noise reduction of seismic records

Random or incoherent noise is an important type of seismic noise, which can seriously affect the quality of the data. Therefore, decreasing the level of this category of noises is necessary for increasing the signal-to-noise ratio (SNR) of seismic records. Random noises and other events overlap each other in time domain, which makes it difficult to attenuate them from seismic records. In this r...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Secrecy of Communications in Data Transmission by Impulses with Unknown Moments of Appearance and Disappearance

We carried out a comparative analysis of the algorithms for detecting a rectangular impulse against Gaussian white noise under either authorized or unauthorized access to the transmitted data. We presupposed that for data transmission the binary communication system is used and that the useful information in the data is whether the signal is present or absent. The case is that unauthorized acce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 1997