High-sensitivity, single-beam n(2) measurements.

نویسندگان

  • M Sheik-Bahae
  • A A Said
  • E W Van Stryland
چکیده

We present a simple yet highly sensitive single-beam experimental technique for the determination of both the sign and magnitude of n(2). The sample is moved along the z direction of a focused Gaussian beam while the repetitively pulsed laser energy is held fixed. The resultant plot of transmittance through an aperture in the far field yields a dispersion-shaped curve from which n(2) is easily calculated. A transmittance change of 1% corresponds to a phase distortion of approximately lambda/250. We demonstrate this method on several materials using both CO(2) and Nd:YAG laser pulses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

Measurement and noise performance of nano

Science and industry demand ever more sensitive measurements on ever smaller systems, as exemplified by spintronics, nanoelectromechanical system, and spin-based quantum information processing, where single electronic spin detection poses a grand challenge. Superconducting quantum interference devices SQUIDs have yet to be effectively applied to nanoscale measurements. Here, we show that a simp...

متن کامل

Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range

 ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...

متن کامل

3D visualization of XFEL beam focusing properties using LiF crystal X-ray detector

Here, we report, that by means of direct irradiation of lithium fluoride a (LiF) crystal, in situ 3D visualization of the SACLA XFEL focused beam profile along the propagation direction is realized, including propagation inside photoluminescence solid matter. High sensitivity and large dynamic range of the LiF crystal detector allowed measurements of the intensity distribution of the beam at di...

متن کامل

Single camera 3D planar Doppler velocity measurements, using two frequency Planar Doppler Velocimetry (2ν-PDV) and imaging fibre bundles

A modified Planar Doppler Velocimetry (PDV) technique, two frequency PDV (2-PDV), is described that allows measurements of the velocity field over a plane defined by a laser light sheet using sequential illumination of the flow with two closely separated (~1GHz) frequencies of laser light. This allows a common-path imaging head to be used containing a single CCD camera instead of the usual cam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 14 17  شماره 

صفحات  -

تاریخ انتشار 1989