Stress-based Design of a Femoral Hip Prosthesis

نویسندگان

  • Michael H. Santare
  • Makarand G. Joshi
  • Suresh G. Advani
  • Shawn P. Riley
  • Freeman Miller
چکیده

INTRODUCTION In the normal hip, stress is distributed over the entire crossection of the femur. Bending and axial compression are the major modes of loading. Following THA, the stress in the bone is significantly different mainly due to the manner in which the load is transferred to the femur (Huiskes, 1990, Huiskes, 1995). In this case, the load is primarily transferred through shear across the bone-cementprostheses interfaces. In addition, the bending displacement in the bone surrounding the stem are reduced because of the relatively high flexural stiffness of the prosthesis. This reduced bending unloads the outer fibers of femur leading to a state of stress shielding. The medial calcar, which experiences a significant reduction in stresses (stress shielding) has been commonly seen to atrophy in in-vivo radiological studies. An apparent solution to this problem would be a prosthesis which loads the proximal end of the femur in a manner similar to the natural state. Recently, a stemless prosthesis design using proximal fixation was developed by Munting and Verhelpen, (1995) and has shown promising initial results. This design is fixed to the lateral side of the proximal femur by means of a bolt. Their invitro experiments showed minimal micromotion and the short-term clinical studies have shown low initial failure rates. The motivating hypothesis for the current study, is that it is possible to develop a new femoral prosthesis component designed specifically to reduce the levels of stress shielding and interfacial shear stress in the femur following total hip arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prosthesis design and stress profile after hip resurfacing: a finite element analysis.

PURPOSE To evaluate the effect of prosthesis design on stress profile in the proximal femur after hip resurfacing. METHODS The von Mises stress profile of the native femur was simulated and compared with that of resurfaced femurs using various prosthetic materials (titanium, cobalt-chrome, ceramic), stem lengths (normal, half, short, and no stem), and femoral head coverage (shell size) [260 d...

متن کامل

Long-Term Follow-Up Results of a Second-Generation Cementless Femoral Prosthesis with a Collar and Straight Distal Fixation Channels

PURPOSE We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems ...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Investigation of creep mechanical characteristics of femoral prostheses by simulated hip replacement

In order to provide creep mechanical parameters for the clinical application of both traditional and reserved anatomy femoral artificial joint replacements, simulated hip replacement femoral stress relaxation and creep experiments were performed. Twenty-four corpse femoral specimens were obtained, with 8 specimens being randomly assigned to the control group and 8 specimens being randomly assig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999