The laryngeal mask airway in infants and children.
نویسندگان
چکیده
PURPOSE To compare the effectiveness of various laryngeal mask airway (LMA) sizes and their performance during positive pressure ventilation (PPV) in paralyzed pediatric patients. METHODS Pediatric patients (n = 158), < 30 kg, ASA 1 or 2 were studied. After paralysis, an LMA of the recommended size was inserted and connected to a volume ventilator. Fibreoptic bronchoscopy (FOB) was performed and graded: 1, larynx only seen; 2, larynx and epiglottis posterior surface seen; 3, larynx, and epiglottis tip or anterior surface seen--visual obstruction of epiglottis to larynx: < 50%; 4, epiglottis down-folded, and its anterior surface seen--visual obstruction of epiglottis to larynx: > 50%; 5, epiglottis down-folded and larynx not seen directly. Inspiratory and expiratory tidal volumes (V(T)), and airway pressure were measured by a pneumo-tachometer, and the fraction of leakage (F(L)) was calculated. In 79 cases, LMA was used for airway maintenance throughout surgery. RESULTS Successful LMA placement was achieved in 98% of cases: three failures were due to gastric insufflation. For LMA # 1, 1.5, 2, and 2.5, FOB grades [median (range)] were 3(1-5), 3(1-5), 1(1-5) and 1(1-3) respectively. In smaller LMAs, the cuff more frequently enclosed the epiglottis (P < .001). F(L) of LMA # 1 was higher than those of LMA # 1.5 and LMA # 2.5 (P < .05), and F(L) of LMA # 2 was higher than that of LMA # 2.5 (P < .05). In the 79 patients, the number of patients experiencing complications decreased as LMA size increased (P < .05). CONCLUSION Use of the LMA in smaller children results in more airway obstruction, higher ventilatory pressures, larger inspiratory leak, and more complications than in older children.
منابع مشابه
Limitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملHemodynamic responses to insertion of the laryngeal mask airway versus Combitube
Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...
متن کاملComparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study
Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical anesthesia
دوره 9 5 شماره
صفحات -
تاریخ انتشار 1997