Fractional labelmaps for computing accurate dose volume histograms
نویسندگان
چکیده
PURPOSE: In radiation therapy treatment planning systems, structures are represented as parallel 2D contours. For treatment planning algorithms, structures must be converted into labelmap (i.e. 3D image denoting structure inside/outside) representations. This is often done by triangulated a surface from contours, which is converted into a binary labelmap. This surface to binary labelmap conversion can cause large errors in small structures. Binary labelmaps are often represented using one byte per voxel, meaning a large amount of memory is unused. Our goal is to develop a fractional labelmap representation containing non-binary values, allowing more information to be stored in the same amount of memory. METHODS: We implemented an algorithm in 3D Slicer, which converts surfaces to fractional labelmaps by creating 216 binary labelmaps, changing the labelmap origin on each iteration. The binary labelmap values are summed to create the fractional labelmap. In addition, an algorithm is implemented in the SlicerRT toolkit that calculates dose volume histograms (DVH) using fractional labelmaps. RESULTS: We found that with manually segmented RANDO head and neck structures, fractional labelmaps represented structure volume up to 19.07% (average 6.81%) more accurately than binary labelmaps, while occupying the same amount of memory. When compared to baseline DVH from treatment planning software, DVH from fractional labelmaps had agreement acceptance percent (1% ΔD, 1% ΔV) up to 57.46% higher (average 4.33%) than DVH from binary labelmaps. CONCLUSION: Fractional labelmaps promise to be an effective method for structure representation, allowing considerably more information to be stored in the same amount of memory.
منابع مشابه
Fractional labelmap representation of anatomical structures
INTRODUCTION: In medical imaging software, structures are often represented using image volumes known as labelmaps. Conversion of structures to labelmap representations results in a loss of information which impacts medical imaging algorithms, including those in radiation therapy (RT) treatment planning. RT treatment planning systems are used to optimize radiation delivery to structures, which ...
متن کاملThree-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
متن کاملDose-volume Analysis of Heart and Lung during 3D Planning of Tangential Breast Cancer Irradiation
Introduction: Breast cancer is becoming more frequently diagnosed at early stages with improved long-term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Materials and Methods: Twenty...
متن کاملDose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation
Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...
متن کاملEvaluation of a clinically intuitive quality assurance method
There is a pressing need for clinically intuitive quality assurance methods that report metrics of relevance to the likely impact on tumor control of normal tissue injury. This paper presents a preliminary investigation into the accuracy of a novel "transform method" which enables a clinically relevant analysis through dose-volume-histograms (DVHs) and dose overlays on the patient's CT data. Th...
متن کامل