Current Density Imaging Using Directly Measured Harmonic Bz Data in MREIT
نویسندگان
چکیده
Magnetic resonance electrical impedance tomography (MREIT) measures magnetic flux density signals through the use of a magnetic resonance imaging (MRI) in order to visualize the internal conductivity and/or current density. Understanding the reconstruction procedure for the internal current density, we directly measure the second derivative of Bz data from the measured k-space data, from which we can avoid a tedious phase unwrapping to obtain the phase signal of Bz . We determine optimal weighting factors to combine the derivatives of magnetic flux density data, [Symbol: see text](2) Bz , measured using the multi-echo train. The proposed method reconstructs the internal current density using the relationships between the induced internal current and the measured [Symbol: see text](2) Bz data. Results from a phantom experiment demonstrate that the proposed method reduces the scanning time and provides the internal current density, while suppressing the background field inhomogeneity. To implement the real experiment, we use a phantom with a saline solution including a balloon, which excludes other artifacts by any concentration gradient in the phantom.
منابع مشابه
Electrical conductivity images of biological tissue phantoms in MREIT.
We present cross-sectional conductivity images of two biological tissue phantoms. Each of the cylindrical phantoms with both diameter and height of 140 mm contained chunks of biological tissues such as bovine tongue and liver, porcine muscle and chicken breast within a conductive agar gelatin as the background medium. We attached four recessed electrodes on the sides of the phantom with equal s...
متن کاملMREIT conductivity imaging based on the local harmonic Bz algorithm: animal experiments
From numerous numerical and phantom experiments, MREIT conductivity imaging based on harmonic Bz algorithm shows that it could be yet another useful medical imaging modality. However, in animal experiments, the conventional harmonic Bz algorithm gives poor results near boundaries of problematic regions such as bones, lungs, and gas-filled stomach, and the subject boundary where electrodes are n...
متن کاملLocal Harmonic Bz Algorithm With Domain Decomposition in MREIT: Computer Simulation Study
Magnetic resonance electrical impedance tomography (MREIT) attempts to provide conductivity images of an electrically conducting object with a high spatial resolution. When we inject current into the object, it produces internal distributions of current density and magnetic flux density. By using a magnetic resonance imaging (MRI) scanner, we can measure B(z) data where z is the direction of th...
متن کاملOptimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
BACKGROUND Magnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface electrodes induces a magnetic flux density distribution inside the imaging object, which results in ...
متن کاملCurrent-Controlled Alternating Steady State Free Precession for Rapid Conductivity Mapping
Introduction: High resolution cross-sectional conductivity (σ) distribution of biological tissues can be measured with magnetic resonance electrical impedance tomography (MREIT) (1), wherein the magnetic flux density (Bz) induced by current injection through a pair of electrodes synchronized with a MR pulse sequence appears as perturbation in image phase, and then the relation between ∇Bz and ∇...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013