Cardiovascular changes following insertion of oropharyngeal and nasopharyngeal airways.

نویسندگان

  • J L Tong
  • J E Smith
چکیده

BACKGROUND The cardiovascular responses following the insertion of oropharyngeal airways in anaesthetized patients have been found to be of little consequence. However, those following the insertion of nasopharyngeal airways have not been studied. The aim of this investigation was to compare the cardiovascular responses to the insertion of oropharyngeal and nasopharyngeal airways in anaesthetized patients. METHODS Twenty-four ASA I or II patients aged 16-65 yr, requiring nasotracheal intubation as part of their anaesthetic management, received a standardized general anaesthetic and were randomly allocated to receive either a nasopharyngeal or an oropharyngeal airway. RESULTS The two groups were similar with respect to age, weight and gender. There was a significant decrease in systolic pressure following the induction of anaesthesia in both groups. Following nasopharyngeal airway insertion, there was a significant rise in systolic pressure above pre-insertion levels (P< or =0.001), though not above pre-induction levels (P=0.808). There was no significant change in the oropharyngeal airway insertion group (P=0.619). At 1 min post-insertion, the mean (sd) systolic pressure in the nasopharyngeal insertion group, 122 (21.6) mm Hg, was significantly greater than that in the oropharyngeal insertion group, 103 (15.3) mm Hg (P=0.017). Diastolic pressure followed a similar pattern. In both groups, heart rate fell after induction and fell further after insertion, and at 4 min post-insertion was significantly lower than pre-induction and pre-insertion levels. There was no significant difference in heart rates between the two groups (P=0.372). CONCLUSIONS The pressor response following the insertion of nasopharyngeal airways in anaesthetized patients is significantly greater than that following the insertion of oropharyngeal airways. However, the mean rise in arterial pressure does not exceed pre-induction level, and thus the response is less severe than that likely to be associated with orotracheal or nasotracheal intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Pharyngeal Airway Dimensions in Cephalograms of Patients with Different Skeletal Patterns

     Background and purpose: Respiratory function of patients is a major part of orthodontic diagnosis and treatment planning. It is affected by the dimensions of the pharyngeal airway. In this study, these dimensions were compared in patients with different skeletal patterns. Materials and methods: This cross-sectional descriptive-analytical study was performed studying the cephalograms of pa...

متن کامل

Comparison of patient-collected and lab technician-collected nasopharyngeal and oropharyngeal swabs for detection of COVID-19 by RT-PCR

Background & Objective:  A simple approach to prevent close contact in healthcare settings during the COVID-19 outbreak is to train patients to collect their own nasopharyngeal and oropharyngeal swabs and deliver them to medical laboratories to have them processed. The aim of our study was to c...

متن کامل

Oropharyngeal and nasopharyngeal airways: I (1880-1995).

PURPOSE During the past decade the laryngeal mask airway (LMA) has dominated literature about airways for use during general anaesthesia. The LMA addresses clearly defined clinical objectives. The purpose of this study is to determine whether those objectives were described collectively with reference to earlier airway designs. METHODS The anaesthesia sections of Index Medicus 1880-1995 were ...

متن کامل

A retrospective cephalometric study on pharyngeal airway space changes after rapid palatal expansion and Herbst appliance with or without skeletal anchorage

BACKGROUND The aim of this study is to investigate the pharyngeal airway space changes in patients treated with rapid palatal expansion (RPE) and Herbst appliance with or without skeletal anchorage. METHODS A 40-patient study group treated with the Herbst RME combination was included; moreover, a comparison between two subgroups based on whether miniscrews were used was evaluated. A subgroup ...

متن کامل

Airway statuses and nasopharyngeal airway use for airway obstruction in syndromic craniosynostosis.

Syndromic craniosynostosis is associated with a high rate of respiratory difficulty, due mainly to midfacial hypoplasia. Nasopharyngeal airway establishment has been reported as the first-line approach to airway obstruction and may obviate the need for a highly invasive tracheotomy. No previous studies have compared airway obstruction status in syndromic craniosynostosis between cases requiring...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 2004