Change in Intraocular Pressure During Point-of-Care Ultrasound
نویسندگان
چکیده
INTRODUCTION Point-of-care ocular ultrasound (US) is a valuable tool for the evaluation of traumatic ocular injuries. Conventionally, any maneuver that may increase intraocular pressure (IOP) is relatively contraindicated in the setting of globe rupture. Some authors have cautioned against the use of US in these scenarios because of a theoretical concern that an US examination may cause or exacerbate the extrusion of intraocular contents. This study set out to investigate whether ocular US affects IOP. The secondary objective was to validate the intraocular pressure measurements obtained with the Diaton® as compared with standard applanation techniques (the Tono-Pen®). METHODS We enrolled a convenience sample of healthy adult volunteers. We obtained the baseline IOP for each patient by using a transpalpebral tonometer. Ocular US was then performed on each subject using a high-frequency linear array transducer, and a second IOP was obtained during the US examination. A third IOP measurement was obtained following the completion of the US examination. To validate transpalpebral measurement, a subset of subjects also underwent traditional transcorneal applanation tonometry prior to the US examination as a baseline measurement. In a subset of 10 patients, we obtained baseline pre-ultrasound IOP measurements with the Diaton® and Tono-Pen®, and then compared them. RESULTS The study included 40 subjects. IOP values during ocular US examination were slightly greater than baseline (average +1.8mmHg, p=0.01). Post-US examination IOP values were not significantly different than baseline (average -0.15mmHg, p=0.42). In a subset of 10 subjects, IOP values were not significantly different between transpalpebral and transcorneal tonometry (average +0.03mmHg, p=0.07). CONCLUSION In healthy volunteer subjects, point-of-care ocular US causes a small and transient increase in IOP. We also showed no difference between the Diaton® and Tono-Pen® methods of IOP measurement. Overall, the resulting change in IOP with US transducer placement is considerably less than the mean diurnal variation in healthy subjects, or pressure generated by physical examination, and is therefore unlikely to be clinically significant. However, it is important to take caution when performing ocular ultrasound, since it is unclear what the change in IOP would be in patients with ocular trauma.
منابع مشابه
Ciliary Body Tuberculosis Presenting with Attacks of Acute Intraocular Pressure Rise
Purpose: To report a rare presentation of ophthalmic tuberculosis. Case Report: A 19-year-old man was referred to the glaucoma clinic due to multiple attacks of increased intraocular pressure (IOP) in his right eye. IOP of the right eye was 50 mmHg, and glaucomatous damage of the optic nerve was present. In gonioscopy, an oval-black lesion was present in the ciliary body band on the temporal si...
متن کاملThe effect of low dose of ketamine on intraocular pressure in patients undergoing cataract surgery
Background: Cataract surgery is one of the most common surgeries in the world, especially in elderly patients, and often performed topically with sedative agents. Ketamine is one of the most commonly used agents and the effect of different doses on intraocular pressure is in dispute. The present study investigates the effect of a low dose of ketamine on intraocular pressure in patients undergoi...
متن کاملEvaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting
Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...
متن کاملEvaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...
متن کاملDetermination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کامل