Size‐based protocol optimization using automatic tube current modulation and automatic kV selection in computed tomography

نویسندگان

  • Robert D. MacDougall
  • Patricia L. Kleinman
  • Michael J. Callahan
چکیده

Size-based diagnostic reference ranges (DRRs) for contrast-enhanced pediatric abdominal computed tomography (CT) have been published in order to establish practical upper and lower limits of CTDI, DLP, and SSDE. Based on these DRRs, guidelines for establishing size-based SSDE target levels from the SSDE of a standard adult by applying a linear correction factor have been published and provide a great reference for dose optimization initiatives. The necessary step of designing manufacturer-specific CT protocols to achieve established SSDE targets is the responsibility of the Qualified Medical Physicist. The task is straightforward if fixed-mA protocols are used, however, more difficult when automatic exposure control (AEC) and automatic kV selection are considered. In such cases, the physicist must deduce the operation of AEC algorithms from technical documentation or through testing, using a wide range of phantom sizes. Our study presents the results of such testing using anthropomorphic phantoms ranging in size from the newborn to the obese adult. The effect of each user-controlled parameter was modeled for a single-manufacturer AEC algorithm (Siemens CARE Dose4D) and automatic kV selection algorithm (Siemens CARE kV). Based on the results presented in this study, a process for designing mA-modulated, pediatric abdominal CT protocols that achieve user-defined SSDE and kV targets is described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of automatic tube potential selection with tube current modulation in coronary CT angiography for obese patients: Comparison with a body mass index-based protocol using the propensity score matching method

BACKGROUND Reduced image quality from increased X-ray scatter and image noise can be problematic when coronary computed tomography angiography (CCTA) imaging is performed in obese patients. The aim of this study was to compare the image quality and radiation dose obtained using automatic tube potential selection with tube current modulation (APSCM) with those obtained using a body mass index (B...

متن کامل

Estimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study

Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...

متن کامل

A Study of Dose Distribution and Image Quality under an Automatic Tube Current Modulation (ATCM) System for a Toshiba Aquilion 64 CT Scanner Using a New Design of Phantom

Automatic tube current modulation (ATCM) systems are available for all CT manufacturers and are used for the majority of patients. Understanding how the systems work and their influence on patient dose and image quality is important for CT users, in order to gain the most effective use of the systems. In the present study, a new phantom was used for evaluating dose distribution and image qualit...

متن کامل

Dimensionality Reduction and Improving the Performance of Automatic Modulation Classification using Genetic Programming (RESEARCH NOTE)

This paper shows how we can make advantage of using genetic programming in selection of suitable features for automatic modulation recognition. Automatic modulation recognition is one of the essential components of modern receivers. In this regard, selection of suitable features may significantly affect the performance of the process. Simulations were conducted with 5db and 10db SNRs. Test and ...

متن کامل

Chest-abdomen-pelvis CT for staging in cancer patients: dose effectiveness and image quality using automated attenuation-based tube potential selection

BACKGROUND Evaluation of automated attenuation-based tube potential selection and its impact on image quality and radiation dose in CT (computed tomography) examinations for cancer staging. METHODS A total of 110 (59 men, 51 women) patients underwent chest-abdomen-pelvis CT examinations; 55 using a fixed tube potential of 120 kV/current of 210 Reference mAs (using CareDose4D), and 55 using au...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016