MEASUREMENT OF THE SCINTILLATION EFFICIENCY OF Na RECOILS IN NaI(Tl) DOWN TO 10 keV NUCLEAR RECOIL ENERGY RELEVANT TO DARK MATTER SEARCHES

نویسنده

  • H. CHAGANI
چکیده

We present preliminary results of measurements of the quenching factor for Na recoils in NaI(Tl) at room temperature, made at a dedicated neutron facility at the University of Sheffield. Measurements have been performed with a 2.45 MeV mono-energetic neutron generator in the energy range from 10 keV to 100 keV nuclear recoil energy. A BC501A liquid scintillator detector was used to tag neutrons. Cuts on pulse-shape discrimination from the BC501A liquid scintillator detector and neutron time-of-flight were performed on pulses recorded by a digitizer with a 2 ns sampling time. Measured quenching factors range from 19% to 26%, in agreement with other experiments. From pulseshape analysis, a mean time of pulses from electron and nuclear recoils are compared down to 2 keV electron equivalent energy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CsI(Tl) for WIMP dark matter searches

We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find that, as with NaI(Tl), pulse shape analysis can be used to discriminate between electron and nuclear recoils down to 4 keV. However, the discrimination factor...

متن کامل

Measurement of Scintillation Efficiencies and Pulse-Shapes for Nuclear Recoils in NaI(Tl) and CaF2(Eu) at Low Energies for Dark Matter Experiments

Measurements have been performed with a 2.85 MeV mono-energetic neutron beam of relative scintillation efficiency and pulse-shape for nuclear and electron recoils in NaI(Tl) and CaF2(Eu). Scintillation efficiencies in NaI(Tl) relative to 60 keV gamma events were found to be 27.5 ± 1.8 % for Na recoils (recoil energy Erec > 4 keV) and 8.6 ± 0.7 % for I recoils (Erec > 10 keV). Relative scintilla...

متن کامل

Characteristics of Alpha, Gamma and Nuclear Recoil Pulses from NaI(Tl) at 10-100 keV Relevant to Dark Matter Searches

Measurements of the shapes of scintillation pulses produced by nuclear recoils, alpha particles and photons in NaI(Tl) crystals at visible energies of 10-100 keV have been performed in order to investigate possible sources of background in NaI(Tl) dark matter experiments and, in particular, the possible origin of the anomalous fast time constant events observed in the UK Dark Matter Collaborati...

متن کامل

Measuring Electron Response in NaI(Tl) using Compton Coincidence Technique

The scintillation efficiency of electron recoils in liquid xenon (LXe) is not well measured at low energies. The Compton coincidence technique (CCT) is set up using a NaI(Tl) detector and HPGe detector to measure the energy dependence of the light yield in the NaI(Tl) detector from which we can extract the scintillation effieciency. This technique allows for the detection of low energy electron...

متن کامل

Nuclear Recoil Measurement in CsI(Tl) Crystal for Cold Dark Matter Detection

There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The scattering signatures by neutrons on a CsI(Tl) detector were studied using a neutron beam generated by a 13 MV Tandem accelerator. The energy spectra of nuclear recoils from 7 keV to 132 keV were measured, and their quenching factors for scintillating light yield were derived. The data represents the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006