Laboratory evaluation of the Chembio Dual Path Platform HIV-Syphilis Assay

نویسندگان

  • Mireille B. Kalou
  • Arnold Castro
  • Amy Watson
  • Heather Jost
  • Stacy Clay
  • Ye Tun
  • Cheng Chen
  • Kevin Karem
  • John N. Nkengasong
  • Ronald Ballard
  • Bharat Parekh
چکیده

BACKGROUND Use of rapid diagnostic tests for HIV and syphilis has increased remarkably in the last decade. As new rapid diagnostic tests become available, there is a continuous need to assess their performance and operational characteristics prior to use in clinical settings. OBJECTIVES In this study, we evaluated the performance of the Chembio Dual Path Platform (DPP®) HIV-Syphilis Assay to accurately diagnose HIV, syphilis, and HIV/syphilis co-infection. METHOD In 2013, 990 serum samples from the Georgia Public Health Laboratory in Atlanta, Georgia, United States were characterised for HIV and syphilis and used to evaluate the platform. HIV reference testing combined third-generation Enzyme Immunoassay and Western Blot, whereas reference testing for syphilis was conducted by the Treponema pallidum passive particle agglutination method and the TrepSure assay. We assessed the sensitivity and specificity of the DPP assay on this panel by comparing results with the HIV and syphilis reference testing algorithms. RESULTS For HIV, sensitivity was 99.8% and specificity was 98.4%; for syphilis, sensitivity was 98.8% and specificity was 99.4%. Of the 348 co-infected sera, 344 (98.9%) were detected accurately by the DPP assay, but 11 specimens had false-positive results (9 HIV and 2 syphilis) due to weak reactivity. CONCLUSION In this evaluation, the Chembio DPP HIV-Syphilis Assay had high sensitivity and specificity for detecting both HIV and treponemal antibodies. Our results indicate that this assay could have a significant impact on the simultaneous screening of HIV and syphilis using a single test device for high-risk populations or pregnant women needing timely care and treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Form II HRP Research Proposal: Project details Utility evaluation of Point-of-Care Tests in Non-Clinical Settings for the Screening of HIV and Syphilis in Men Who Have Sex with Men 1. Project summary

Serologic tests are the diagnostic tests of choice for HIV and syphilis. There are two types of serological tests (treponemal and non-treponemal tests) for laboratory diagnosis of syphilis. Traditionally, one non-treponemal assay is used for screening and a treponemal assay is used for confirmation for syphilis. For diagnosis of HIV EIAs are used for screening and Western blot for confirmation ...

متن کامل

Comparison of Rapid Point-of-Care Tests for Detection of Antibodies to Hepatitis C Virus

Background.  Hepatitis C is one of the most prevalent blood-borne diseases in the United States. Despite the benefits of early screening, among 3.2 million Americans who are infected with hepatitis C virus (HCV), 50%-70% are unaware of their infection status. Methods.  Data were collected between 2011 and 2014, from 1048 clients who were in the following groups: (1) injection drug users, (2) wo...

متن کامل

Laboratory evaluation of a dual rapid immunodiagnostic test for HIV and syphilis infection.

New dual tests for HIV and syphilis have been developed. Our study aimed to evaluate the laboratory performance of a dual rapid immunodiagnostic test for HIV and syphilis. Our evaluation showed high performance of this dual rapid test, which should be considered for implementation to increase screening coverage and efficiency.

متن کامل

Multisite Laboratory Evaluation of a Dual Human Immunodeficiency Virus (HIV)/Syphilis Point-of-Care Rapid Test for Simultaneous Detection of HIV and Syphilis Infection

BACKGROUND Recently, test developers have created rapid point-of-care tests that can simultaneously detect multiple infections within the same specimen using a single device. The SD BIOLINE Duo HIV/Syphilis rapid point-of-care test uses a solid-phase immunochromatographic assay to detect immunoglobulin (Ig)G, IgM, and IgA antibodies to human immunodeficiency virus (HIV)-specific antigens (HIV-1...

متن کامل

Sensitivity and Specificity of Point-of-Care Rapid Combination Syphilis-HIV-HCV Tests

BACKGROUND New rapid point-of-care (POC) tests are being developed that would offer the opportunity to increase screening and treatment of several infections, including syphilis. This study evaluated three of these new rapid POC tests at a site in Southern California. METHODS Participants were recruited from a testing center in Long Beach, California. A whole blood specimen was used to evalua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016