Validity and reliability of the Wattbike cycle ergometer.
نویسندگان
چکیده
The purpose of this study was to assess the validity and reliability of the Wattbike cycle ergometer against the SRM Powermeter using a dynamic calibration rig (CALRIG) and trained and untrained human participants. Using the CALRIG power outputs of 50-1 250 W were assessed at cadences of 70 and 90 rev x min(-1). Validity and reliability data were also obtained from 3 repeated trials in both trained and untrained populations. 4 work rates were used during each trial ranging from 50-300 W. CALRIG data demonstrated significant differences (P<0.05) between SRM and Wattbike across the work rates at both cadences. Significant differences existed in recorded power outputs from the SRM and Wattbike during steady state trials (power outputs 50-300 W) in both human populations (156±72 W vs. 153±64 W for SRM and Wattbike respectively; P<0.05). The reliability (CV) of the Wattbike in the untrained population was 6.7% (95%CI 4.8-13.2%) compared to 2.2% with the SRM (95%CI 1.5-4.1%). In the trained population the Wattbike CV was 2.6% (95%CI 1.8-5.1%) compared to 1.1% with the SRM (95%CI 0.7-2.0%). These results suggest that when compared to the SRM, the Wattbike has acceptable accuracy. Reliability data suggest coaches and cyclists may need to use some caution when using the Wattbike at low power outputs in a test-retest setting.
منابع مشابه
Reliability of a 2-bout exercise test on a wattbike cycle ergometer.
PURPOSE To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). METHODS Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg-1 · min-1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured t...
متن کاملThe reliability of a 30-s sprint test on the Wattbike cycle ergometer.
PURPOSE To determine the reliability of a 30-s sprint cycle test on the Wattbike cycle ergometer. METHODS Over 3 consecutive weeks, 11 highly trained cyclists (mean ± SD; age 31 ± 6 y, mass 74.6 ± 10.6 kg, height 180.5 ± 8.1cm) completed four 30-s maximal sprints on a Wattbike ergometer after a standardized warm-up. The sprint test implemented a "rolling start" that consisted of a 60-s preloa...
متن کاملThe validity and reliability of a sample of 10 Wattbike cycle ergometers.
The purpose of the study was to assess the validity and inter-bike reliability of 10 Wattbike cycle ergometers, and to assess the test-retest reliability of one Wattbike. Power outputs from 100 to 1000 W were applied using a motorised calibration rig (LODE) at cadences of 70, 90, 110 and 130 rev · min-1, which created nineteen different intensities for comparison. Significant relationships (P <...
متن کاملReproducibility of a Laboratory Based 1-km Wattbike Cycling Time Trial in Competitive Cyclists
The purpose of this study was to evaluate the reliability of a 1-km cycling time trial using a Wattbike cycling ergometer in competitive cyclists. Ten competitive male cyclists (mean ± SD; 63.9 ± 5.1 mL•kg -1 •min -1 ) performed a VO2max test and a familiarization of the 1-km time trial (TT) on the same day, and 3 separate 1-km TT (TT1, TT2 and TT3) separated by >24 hours. Mean performance time...
متن کاملValidity and reliability of the Chester step test for prediction of the aerobic capacity among Iranian students
Background: Assessment of aerobic capacity is of vital importance in both general community and occupational settings. Valid, reliable and feasible tests are required to indicate the functionality of cardiopulmonary system. The present study was carried out aiming to evaluate the suitability of the Chester step test (CST) as a field test to measure the Iranians’ aerobic capacity. Materials ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of sports medicine
دوره 31 10 شماره
صفحات -
تاریخ انتشار 2010