The safety and feasibility of transradial cutting balloon angioplasty: immediate results, benefits, and limitations.

نویسندگان

  • Cheng-Hsu Yang
  • G Bih-Fang Guo
  • Hsueh-Wen Chang
  • Hon-Kan Yip
  • Kelvin Hsieh
  • Chi-Yung Fang
  • Chien-Jen Chen
  • Wei-Ching Hung
  • Chi-Ling Hang
  • Chiung-Jen Wu
چکیده

Cutting balloon angioplasty can reduce the restenosis rate more than conventional balloon angioplasty, but is traditionally performed through a femoral artery. However, it is not clear how useful a transradial approach would be for cutting balloon angioplasty. This study was conducted to examine the safety, feasibility, and limitations of transradial as opposed to transfemoral cutting balloon angioplasty. From November 1999 to August 2001, 177 patients underwent cutting balloon coronary angioplasty. We compared the success rate, angiographic results, and complication rates of two groups of patients, those undergoing transradial (168 lesions from 153 patients) and those undergoing transfemoral (24 lesions from 24 patients) cutting balloon angioplasty. In both groups of patients who had similar clinical and target lesion characteristics. the percentage of lesions that required balloon predilation (27.4% vs 29.2%). stenting (7.7% vs 4.2%), and adjunct balloon dilation (28.0% vs 33.3%) due to dissection (35.7% vs 33.3%) or suboptimal results were comparable. Both approaches achieved a 100% primary success rate with similar acute gain (2.02 +/- 0.68 mm vs 1.94 +/- 0.70 mm), residual (luminal) diameter stenosis (19.2 +/- 11.7% vs 17.0 +/- 12.7%). proportion of lesions that achieved TIMI 3 flow (98.8% vs 100%), and clinical success rate (98.8% vs 95.8%). However, patients undergoing transradial cutting balloon angioplasty had earlier ambulation and a significantly shorter hospital stay than those undergoing a transfemoral approach (2.80 +/- 2.67 days vs 4.75 +/- 5.44 days, P = 0.005). We conclude that the transradial approach is a feasible and safe alternative to the transfemoral approach for cutting balloon angioplasty. In addition, it offers patients early ambulation and a short hospital stay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting

Background Aortic Coarcatation (CoA) is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs). Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA). We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty wi...

متن کامل

BALLOON ANGIOPLASTY IN NATIVE AORTIC COARCTATION: RESULT S IN SHIRAZ AND REVIEW OF ARTICLES

Balloon angioplasty for aortic coarctation was introduced in 1979 for the fust time.1 This procedure soon became the choice treatment for restenosis of operated coarctation,2-5 but remains controversial for native (unoperated) coarctation. However, it seems to be rapidly becoming the intervention of choice for relief of unoperated coarctation as well. In this study, we evaluate the outcome ...

متن کامل

Feasibility of transradial coronary angiography and angioplasty in Chinese patients.

OBJECTIVE To assess the clinical applicability, efficacy, and safety of coronary angiography and angioplasty via a transradial approach in local Chinese patients. DESIGN Prospective case series. SETTING Regional hospital, Hong Kong. PATIENTS All patients undergoing coronary angiography and coronary angioplasty between 1 January and 30 June 2004. INTERVENTIONS Transradial coronary angiog...

متن کامل

Rotational atherectomy via transradial access in the percutaneous treatment of chronic coronary total occlusion with rare complication of coronary guidewire transection

Introduction C total coronary occlusion remains one of the limitations of percutaneous transluminal coronary angioplasty, and few therapeutic devices are specifically designed to address this problem. Despite advances in device technology, the management of resistant, calcific lesions remains one of the greatest challenges in successful chronic total coronary occlusion intervention. Established...

متن کامل

Renal artery rupture following cutting balloon angioplasty for fibromuscular dysplasia: a case report

INTRODUCTION Angioplasty with the use of cutting balloons has been suggested by some case reports and small series for the treatment of renal artery stenoses that are resistant to conventional balloon catheters. Based on this limited experience, the use of this technology has been suggested as safe. Herein, we report a renal artery rupture following angioplasty with a cutting balloon. The compl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese heart journal

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 2003