Turbidimetry of rheumatoid factor in serum with a centrifugal analyzer.

نویسندگان

  • L Borque
  • M Yago
  • C Mar
  • C Rodriguez
چکیده

We describe the simple, rapid turbidimetry of IgM rheumatoid factor in human serum by use of the Cobas-Bio centrifugal analyzer. Heat-aggregated human IgG is used as the antigen. The immunoturbidimetric reaction is monitored at 340 nm for 300 s, and the changes in absorbance after the antigen is added are used to prepare the standard curve. Test results are calculated from the stored curve and reported in int. units/mL, based on comparison with the WHO reference serum for rheumatoid factor. There is no interference from bilirubin (up to 340 mumol/L) or hemoglobin (up to 5600 mg/L). Serum samples with a triglyceride concentration greater than 2.20 mmol/L must be cleared of lipids before analysis. The standard curve is linear from 30 to 500 int. units/mL. Precision, accuracy, linearity, and sensitivity are quite acceptable. The CV was generally less than 5% for different concentrations of rheumatoid factor. Results agree well with those by a rate-nephelometric procedure on the Beckman ICS system (rs = 0.932). However, both correlate poorly with a modified classical Waaler-Rose test. Of 47 patients with rheumatoid arthritis, 34 had IgM rheumatoid factor in their serum, but the measured value did not reflect the activity of the disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced-latex-agglutination assay for C-reactive protein in serum, with use of a centrifugal analyzer.

This is an improved assay of C-reactive protein in serum, for use with the Baker "Encore" centrifugal analyzer. Features of this assay include: 250-specimen throughput per hour, within-batch CV 2.2%, between-batch CV 2.7%, no antigen-excess problems up to 1000 mg/L, negligible interference from rheumatoid factor, and good correlation (r = 0.99) with radial immunodiffusion. The method is inexpen...

متن کامل

Diagnostic value of third generation anti-cyclic citrullinated peptide assay in rheumatoid factor negative rheumatoid arthritis

Objective: This study aimed to evaluate the diagnostic usefulness of second and third generation anticyclic citrullinated peptide (anti-CCP2 and anti-CCP3) assays in Chinese patients with rheumatoid arthritis (RA), and to identify the potential advantages of anti-CCP3 diagnosis in rheumatoid factor (RF) negative RA patients. Methods: Serum samples were obtained from 148 RA patients and 120 cont...

متن کامل

Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.

We have developed a centrifugal analyzer with both fluorescence/light-scatter and conventional absorbance optics. The instrument is used in this investigation to study the formation of antigen-antibody complexes by light scattering and turbidimetric measurements, and to develop assays for human immunoglobulins G, A, and M. Concentrations are calculated from a nonlinear least-squares fit of cali...

متن کامل

Automated enhanced latex agglutination assay for rheumatoid factors in serum.

This improved assay of rheumatoid factors in serum, described here for use with the Baker "Encore" centrifugal analyzer, is efficient, with 250-sample throughput per hour; reproducible, with between-batch CV = 5% and within-batch CV = 2% (mid-assay range); and results correlate well (r = 0.9) with those by other methods. The method is fully quantitative and automated, involves no predilution st...

متن کامل

Characterization and elimination of a factor in serum that interferes with turbidimetry and nephelometry of lipase.

We studied a serum component ("pseudolipase") that interferes with both turbidimetric and nephelometric lipase measurements. Pseudolipase activity in serum was found in the presence of rheumatoid factor and in other disorders of active immune processes. The incidence of this interferent in sera seems to be greater than reported previously. We describe a method for eliminating its effect without...