Modeling correlation indices between bladder and Foley's catheter balloon dose with CT-based planning using limited CT slices in intracavitary brachytherapy for carcinoma of cervix.

نویسندگان

  • Arun S Oinam
  • Jayant Sastri Goda
  • Sidharth Dubey
  • Anup Bhardwaj
  • Firuza D Patel
چکیده

PURPOSE To derive and validate an index to correlate the bladder dose with the catheter balloon dose using limited computed tomography (CT) slices. MATERIALS AND METHODS Applicator geometry reconstructed from orthogonal radiographs were back-projected on CT images of the same patients for anatomy-based dosimetric evaluation. The correlation indices derived using power function of the catheter balloon dose and the bladder volume dose were validated in 31 patients with cervical cancer. RESULTS There was significant correlation between International Commission on Radiation Units (ICRU)-38 balloon reference dose (Dr) and the dose received by 25% bladder volume (D(25)) (P< 0.0001). Significant correlation was also found between the reference dose of mid-balloon point (D(rm)) and the dose to D(25) (P < 0.0001). Average percentage difference [100 x (observed index - expected index)/ expected index] of observed value of I'25 (index for the dose to D25 bladder with respect to mid-balloon reference point) from that of expected value was 0.52%, when the index was modeled with reference dose alone. Similarly the average percentage difference for I'10cc (index for the dose to 10 cc volume of bladder with respect to mid balloon point) was 0.84%. When this index was modeled with absolute bladder volume and reference dose, standard deviation of the percentage difference between observed and expected index for D(rm) reduced by approximately 2% when compared to D(r). CONCLUSION For clinical applications, correlation index modeled with reference dose and volume predicts dose to absolute volume of bladder. Correlation index modeled with reference dose gives a good estimate of dose to relative bladder volume. From our study, we found D(rm) to be a better indicator of bladder dose than D(r).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

Effect of bladder distension on dosimetry of organs at risk in computer tomography based planning of high-dose-rate intracavitary brachytherapy for cervical cancer

PURPOSE Distension and shape of urinary bladder may vary during intracavitary brachytherapy (ICBT) for cervical cancer, significantly affecting doses to bladder, rectum, sigmoid colon and small intestine and consequently late radiation toxicities. This study is to evaluate the effects of different fixed volume bladder distention on dosimetry, assessed by three dimensional image based planning, ...

متن کامل

Non isocentric film-based intracavitary brachytherapy planning in cervical cancer: a retrospective dosimetric analysis with CT planning

PURPOSE To compare intracavitary brachytherapy dose estimation for organs at risk (bladder and rectum) based on semi-orthogonal reconstruction of radiographs on non-isocentric X-ray unit and Computed Tomography (CT) - based volumetric planning in cervical cancer. MATERIAL AND METHODS Bladder and rectal points as per International Commission on Radiation Units and Measurements (ICRU) report 38...

متن کامل

CT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software

Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages ...

متن کامل

Dosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapy

The purpose is to compare CT-based dosimetry with International Commission on Radiation Units and Measurements (ICRU 38) bladder and rectum reference points in patients of carcinoma of uterine cervix treated with intracavitary brachytherapy (ICA). Twenty-two consecutive patients were evaluated. Orthogonal radiographs and CT images were acquired and transferred to PLATO planning system. Bladder ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cancer research and therapeutics

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2008