Description of a new non-injectable connector to reduce the complications of arterial blood sampling.
نویسندگان
چکیده
Arterial cannulation is associated with complications including bacterial contamination, accidental intra-arterial injection and blood spillage. We performed a series of audits and experiments to gauge the potential for these, as well as assess the possible contribution of a new device, the Needle-Free Arterial Non-Injectable Connector (NIC), in reducing these risks. The NIC comprises a needle-free connector that prevents blood spillage and a one-way valve allowing aspiration only; once screwed onto the side port of a three-way tap, the device can only be removed with difficulty. We performed a clinical audit of arterial monitoring systems in our intensive care unit, which showed an incidence of bacterial colonisation of five in 86 (6%) three-way tap ports. We constructed a manikin simulation experiment of the management of acute bradycardia, in which trainee doctors were required to inject atropine intravenously. Ten of 15 (66%) doctors injected the drug into the three-way tap of the arterial monitoring system rather than into the intravenous cannula or the central venous catheter. In a laboratory study, we replicated the arterial blood sampling and flushing sequence from a three-way tap, with the syringes attached either directly to the three-way tap port or to a NIC attached to the port. The first (discard) syringe attached to the three-way tap was contaminated with bacteria. Bacterial growth was found in 17 of 20 (85%) downstream flushed samples (corresponding to the patient's circulation) when the three-way tap was accessed directly, compared to none of 20 accessed via the NIC (p < 0.0001). Growth was found on all of 20 (100%) ports accessed directly compared to none of 20 accessed via the NIC (p < 0.0001). The NIC effectively prevents bacteria from contaminating sampling lines. As its design also prevents accidental intra-arterial injection, we suggest that it can reduce complications of arterial monitoring.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملتاثیر قنداق کردن بر پاسخهای فیزیولوژیک درد ناشی از جایگذاری لوله بینی _ معدی در نوزادان نارس: کارآزمایی بالینی طرح متقاطع
Background: Premature newborns undergo numerous painful procedures during their process of care and treatment. Nurses can help reduce the complications of pain through various non-medicinal methods. The present study was therefore conducted to assess the effect of swaddling on physiological pain responses of premature infants to Nasogastric Tube Insertion at 29 Bahman Hospital of Tabriz, affi...
متن کاملFactors affecting Discontinuation of the Once-a-month Injectable Contraceptive (Cyclofem) in Neyshabur, Iran
Background & aim: The developing countries have the contraceptive prevalence rate of 43%. Contraceptive discontinuation accounts for a large number of unintended pregnancies in these countries. The present study aimed to investigate the factors associated with Cyclofem discontinuation. Methods: This historical cohort study was conducted on 198 females, selected through cluster and Poisson sampl...
متن کاملتأثیر اسپرومتری تشویقی، بر میزان اکسیژناسیون بیماران پس از جراحی پیوند عروق کرونر بدون کاربرد پمپ قلبی ریوی
Introduction: Arterial hypoxemia is one of the main pulmonary complications after coronary artery bypass graft surgery. Therefore, several proceedings have been recommended to reduce the complications, and to improve arterial hypoxemia as well as arterial blood gas parameters such as incentive spirometry. This study intended to investigate the effect of incentive spirometry on patients´ oxygen...
متن کاملTEMPERATURE CORRECTION OF ARTERIAL BLOOD pH AND CO2 TENSION IN NEWBORN INFANTS: A NEW SOLUTION FOR AN OLD PROBLEM
The acid-base status and arterial blood gas change with temperature variation. To determine the changes in arterial pH and pC02, arterial blood samples of 50 neonates with different clinical conditions were examined at temperatures of 35 to 42°C with an increment of 0.5° C, which resulted in two nonlinear equations with perfect fit on data. The temperature correction factors of these equati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anaesthesia
دوره 70 1 شماره
صفحات -
تاریخ انتشار 2015