Vector analysis of evolutive corneal astigmatic changes in keratoconus.
نویسندگان
چکیده
PURPOSE To evaluate by vector analysis the corneal astigmatic changes occurring in keratoconic corneas during a 3-year follow-up and to determine the relationship between these changes and other clinical changes. METHODS Keratoconic eyes (n = 114) of 75 patients ranging in age from 14 to 70 years were retrospectively reviewed in four different centers. In all cases, a 3-year follow-up was completed after the diagnosis of keratoconus. Visual, refractive, keratometric, aberrometric, internal astigmatism (IA), and pachymetric changes were evaluated during the follow-up. In addition, corneal astigmatic changes were evaluated by examining the following parameters, using a modification of the Alpins vectorial method: evolutive astigmatism (EA) and angle of error (AE). RESULTS An increase in the magnitude of refractive (P = 0.02) and corneal astigmatism (P = 0.05) was found. The mean magnitude of EA was 1.21 ± 0.97 D at 3 years, with no significant changes at each annual visit (P ≥ 0.52). Mean absolute AE increased significantly by the end of the follow-up (P < 0.01). Absolute AE and the increase in corneal astigmatism were found to correlate at 2 years (r = 0.675, P < 0.01). This correlation became poorer at 3 years (r = 0.352, P = 0.02). The magnitude of the EA was also found to be significantly correlated with central corneal thinning (r = -0.441, P = 0.02). Multiple regression analysis revealed that the magnitude of EA at 3 years correlated significantly with the baseline sphere and IA (R² = 0.86, P < 0.01). CONCLUSIONS Corneal vector astigmatic changes are related to some signs of keratoconus progression and are therefore predictive.
منابع مشابه
Fusion of Different Corneal Parameters to Improve the Diagnosis of Keratoconus
Purpose: To diagnose keratoconus from healthy eyes, as well as suspected keratoconus. Methods: Certain parameters were extracted from Casia, Corvis, and Pentacam HR devices for 3 groups of healthy, with keratoconus, and suspected keratoconus. This study was performed on 340 eyes with keratoconus, 310 normal eyes, and 350 suspected keratoconus. The processing method involved the fusion of featur...
متن کاملCorneal biomechanical properties in normal, regular astigmatic, and keratoconic eyes
Corneal hysteresis (CH) is a parameter which measures the viscoelastic behaviour of the cornea, indicating its biomechanical integrity1. Some clinical conditions such as keratoconus, Fuchs corneal dystrophy, high myopia, glaucoma and corneal refractive surgery, may induce changes in corneal biomechanical properties, leading to a decrease in CH2-6. Astigmatism, a refractive error related to corn...
متن کاملویژگیهای بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری
Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...
متن کاملRisk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty
Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...
متن کاملQuantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data.
PURPOSE To assess quantitatively corneal irregular astigmatism in association with best spectacle-corrected visual acuity. METHODS Refractive powers on a mire ring measured with computerized videokeratography were decomposed, using the Fourier series harmonic analysis. Extracting spherical and regular astigmatic components, the remaining irregular astigmatic component was quantified on rings ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 7 شماره
صفحات -
تاریخ انتشار 2011