Threshold estimates and superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse duration.
نویسندگان
چکیده
The study objective was to estimate the pressure threshold (ED(05), effective dose, or in situ peak rarefactional pressure associated with 5% probability of lesions) of ultrasound (US)-induced lung hemorrhage as a function of pulse duration (PD) in adult rats. A total of 220 10- to 11-week-old 250-g female Sprague-Dawley rats (Harlan) were randomly divided into 20 ultrasonic exposure groups (10 rats/group) and one sham group (20 rats). The 20 ultrasonic exposure groups (2.8-MHz; 10-s exposure duration; 1-kHz PRF; -6-dB pulse-echo focal beam width of 470 microm) were divided into four PD groups (1.3, 4.4, 8.2 and 11.6 micros) and, for each PD group, there were five in situ peak rarefactional pressures (range between 4 and 9 MPa). Rats were weighed, anesthetized, depilated, exposed, and euthanized under anesthesia. The left lung was removed and scored for the occurrence of hemorrhage. If hemorrhage was present, the lesion surface area and depth were measured. Individuals involved in animal handling, exposure and lesion scoring were "blinded" to the exposure conditions. Logistic regression analysis was used to examine the dependence of the lesion occurrences, and Gaussian tobit regression analysis was used to examine the dependence of the lesion surface areas and depths on in situ peak rarefactional pressure and PD. Threshold results are reported in terms of ED(05). For PDs of 1.3, 4.4, 8.2 and 11.6 micros, respectively, lesion occurrence ED(05)s were 3.1, 2.8, 2.3 and 2.0 MPa with standard errors around 0.6 MPa. Lesion size ED(05)s showed similar values. A mechanical index (MI) of 1.9, the US Food and Drug Administration (FDA) regulatory limit of diagnostic US equipment, is equivalent to the adult rat's in situ peak rarefactional pressure of 4.0 MPa. PDs of 8.2 and 11.6 micros had ED(05)s more than 2 standard errors below 4.0 MPa, indicating that the ED(05)s of these two PDs are statistically significantly different from 4.0 MPa. The ED(05) threshold levels for a PD of 1.3 micros are consistent with previous US-induced lung hemorrhage studies. As the PD increases, the ED(05) levels decrease, suggesting greater likelihood of lung damage as the PD increases. All of the ED(05)s are less than the FDA limit.
منابع مشابه
Role of Pulse Repetition Frequency and Exposure Duration on the Superthreshold Behavior of Ultrasound-Induced Lung Hemorrhage in Adult Mice and Rats
Superthreshold behavior for ultrasound-induced lung hemorrhage was investigated in 150 mice and 150 rats at 2.8 MHz to assess the role of pulse repetition frequency (PRF) and exposure duration (ED). Each species was divided into 15 exposure groups (10 per group) for a 3x5 randomized factorial design (3 EDs of 5, 10 and 20 s; and 5 PRFs of 25, 50, 100, 250 and 500 Hz). The in situ peak rarefacti...
متن کاملSuperthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.
OBJECTIVE The purpose of this study was to enhance the findings of an earlier ultrasound-induced lung hemorrhage study (Ultrasound Med Biol 2003; 29:1625-1634) that estimated pressure thresholds as a function of pulse duration (PD: 1.3, 4.4, 8.2, and 11.6 micros; 2.8 MHz; 10-s exposure duration [ED]; 1-kHz pulse repetition frequency [PRF]). In this study, the roles of PRF and PD were evaluated ...
متن کاملThreshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.
The objective of this study was to assess the threshold and superthreshold behavior of ultrasound (US)-induced lung hemorrhage in adult rabbits to gain greater understanding about species dependency. A total of 99 76 +/- 7.6-d-old 2.4 +/- 0.14-kg New Zealand White rabbits were used. Exposure conditions were 5.6-MHz, 10-s exposure duration, 1-kHz PRF and 1.1-micros pulse duration. The in situ (a...
متن کاملThreshold estimation and superthreshold behavior of ultrasound-induced lung hemorrhage in rats: role of age dependency.
Age-dependent threshold and superthreshold behaviors of ultrasound-induced lung hemorrhage were investigated with one hundred ten 12.6 +/- 0.8-d-old rats, one hundred ten 22.9 +/- 0.8-d-old rats, and one hundred 57.7 +/- 3.9-d-old rats. Exposure conditions were: 2.8 MHz, 10-s exposure duration, 1-kHz pulse repetition frequency and 1.3-mus pulse duration. The in situ (at the pleural surface) pea...
متن کاملThreshold Estimates of Ultrasound-induced Lung Hemorrhage in Adult Rats: Role of Pulse Duration
The pressure threshold of ultrasound-induced lung hemorrhage has been estimated as a function of pulse duration (PD) in adult rats. A total of 220 10to 11week-old 250-gram female Sprague-Dawley rats (Harlan) were randomly divided into 20 ultrasonically exposed groups (10 rats/group) and one sham group (20 rats). The 20 ultrasonically exposed groups (2.8 MHz; 10-s exposure duration; 1-kHz PRF) w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasound in medicine & biology
دوره 29 11 شماره
صفحات -
تاریخ انتشار 2003