Technology Report Industrial refrigeration and chilled glycol and water applications
نویسنده
چکیده
Ph: 02 9995 5000 (switchboard) Ph: 131 555 (environment information and publication requests) Ph: 1300 361 967 (natioanl parks, climate change and energy efficiency information and publication requests) The Office of Environment and Heritage, Department of Premier and Cabinet and the State of NSW are pleased to allow this material to be reproduced in whole or in part for educational and non-commercial use, provided the meaning is unchanged and its source, publisher and authorship are acknowledged. Office of Environment and Heritage, Department of Premier and Cabinet has compiled the Industrial refrigeration and chilled glycol and water application technology report in good faith, exercising all due care and attention. Office of Environment and Heritage does not accept responsibility for any inaccurate or incomplete information supplied by third parties. No representation is made about the accuracy, completeness or suitability of the information in this publication for any particular purpose. OEH shall not be liable for any damage which may occur to any person or organisation taking action or not on the basis of this publication. Readers should seek appropriate advice when applying the information to their specific needs. Industrial refrigeration and chilled glycol and water applications 03 This report was prepared on behalf of the Office of Environment and Heritage by Minus40, and is based on calculations and energy modelling conducted in mid 2010. Modelling was based on conventional single and two stage industrial refrigeration systems. Arbitrary load profiles, representative of common industrial refrigeration applications, were used to represent refrigeration plant duty. Ambient weather conditions were factored into the modelling and were based on records obtained from the Australian Bureau of Meteorology. Energy saving technologies were modelled as variants of the conventional single or two stage refrigeration plants. 04 Other criteria like functionality and construction costs are frequently given higher priority. The energy costs of a refrigeration plant could be reduced by around 40 per cent, possibly more, through adoption of the most energy efficient equipment and techniques. A total of 15 energy-saving technologies have been identified in this report, and while many require capital outlays, a series of verified case studies in the report indicate the payback period is often less than three years. With rising energy costs and growing environmental awareness, there is a growing need to reduce power consumption in the industrial refrigeration sector in NSW. This report outlines 15 energy saving technologies available to increase the energy efficiency …
منابع مشابه
P-139: Ram Sperm Motility Following 48 Hours of Refrigeration: Evaluation of Different Extenders for The Preservation of Ram Semen in Liquid State
Background: The application of laparoscopic method for intrauterine insemination is limited in sheep industry by the high cost of equipment and low pregnancy rate of frozen-thawed spermatozoa. Both disadvantages could be decreased if chilled ram semen is transported to the farms and inseminated through cervix. Semen extender provides the requirements for sperm and affects its motility, viabilit...
متن کاملAn ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard "chilled-mirror" dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments h...
متن کاملMulti-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries
The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...
متن کاملStudy of the performance of a solar adsorption cooling system
This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...
متن کاملPhysico-Acoustic Study on Thermal Conductivity of Silver Nanofluid
Low transmission of heat is one of the major problems for heat exchanger fluids in many industrial and scientific applications. This includes cooling of the engines, high power transformers to heat exchangers in solar hot water panels or in refrigeration systems. In order to tackle these problems in thermal industries, nanofluids could play a significant role as excellent heat exchanger materia...
متن کامل