A method for measuring cerebral hemispheric blood flow and metabolism.

نویسندگان

  • J S Meyer
  • Y Shinoara
چکیده

A Method for Measuring Cerebral Hemispheric Blood Flow and Metabolism • A new method for measuring cerebral hemispheric blood flow together with metabolism using an injection of a 5 ml bolus of hydrogen-saturated saline into each internal carotid artery is described. This method was extensively evaluated in the monkey prior to being used in man. Under fluoroscopic control, a catheter was inserted into each cerebral transverse sinus via the basilic veins. Hemispheric blood flow was calculated from the clearance curves of hydrogen from the transverse sinus following injection using a formula based upon the Stewart-Hamilton principle. Hemispheric metabolic index for oxygen was estimated using a new formula by assuming that the distribution of hydrogen into each transverse sinus following injection of the bolus indicates the distribution of the blood from each hemisphere into each transverse sinus. This method has certain advantages over the conventional method for measuring cerebral blood flow, since the actual geometry of the brain in which the blood flow measured is known and simultaneous estimations of hemispheric metabolism are possible. Abnormalities of hemispheric blood flow and metabolism have been measured in 30 patients suffering from various neurological disorders including occlusion of one internal carotid artery. The new formula for estimating hemispheric metabolism is applicable to radioisotopic and other indicator injection methods in which blood is sampled from the cerebral transverse sinuses or internal jugular veins. It was also shown that the transverse sinus distribution of blood derived from each cerebral hemisphere varies from one individual to another. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of cerebral hemispheric blood flow by intracarotid injection of hydrogen gas. Validation of the method in the monkey.

To develop a reliable method for measuring hemispheric blood flow and metabolism in man, the clearance of hydrogen was measured in the cerebral lateral sinus blood of macaque monkeys after intracarotid injection. Hydrogen is an inert gas and its clearance from cerebral venous blood depends solely on arterial inflow, and since it is highly diffusible, rapid equilibrium is maintained between brai...

متن کامل

Measurement of Cerebral Hemispheric Blood Flow by Intracarotid Injection of Hydrogen Gas

To develop a reliable method for measuring hemispheric blood flow and metabolism in man, the clearance of hydrogen was measured in the cerebral lateral sinus blood of macaque monkeys after intracarotid injection. Hydrogen is an inert gas and its clearance from cerebral venous blood depends solely on arterial inflow, and since it is highly diffusible, rapid equilibrium is maintained between brai...

متن کامل

Abnormal hemispheric blood flow and metabolism despite normal angiograms in patients with stroke.

Abnormal Hemispheric Blood Flow and Metabolism Despite Normal A ngiograms in Patients with Stroke • Hemispheric blood flow (HBF) and metabolism were measured using the intracarotid injection of hydrogen-saturated saline in a group of patients with unilateral hemispheric infarction, some of whom had normal angiograms. Blood flow was calculated from the formula derived from the StewartHamilton pr...

متن کامل

Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio

 Objective(s): Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H215O positron emission tomography. Clarification of differences in r...

متن کامل

تغییر سرعت و مقایسه جریان خون نیمکره‌های تکلمی در افراد سالم چپ و راست دست با سونوگرافی داپلر ترانس کرانیال عملکردی

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tsty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 1 6  شماره 

صفحات  -

تاریخ انتشار 1970