Timber Chips as the Insulation Material for Energy Saving in Prefabricated Offices
نویسندگان
چکیده
This research demonstrates the feasibility of a roof insulation method for prefabricated offices that uses vinyl packed timber chips to reduce air conditioning loads (hereinafter referred to as AC loads) and which also improves indoor thermal comfort. The advantages of the new roof insulation method were revealed through comparing the impacts of four roof types on prefabricated offices. The AC load and indoor thermal comfort (surface temperature and air temperature) were evaluated. The disposal of scrap timber discarded from building construction projects is costing money, and is also a waste of natural resources. The assessment of a new roof insulation method with timber chips demonstrates the advanced usage of timber chips, reducing the environmental load in the building construction process. On the other hand, since prefabricated offices have lower thermal storage capacities and are less airtight than RC (reinforced concrete) or S (steel) structured buildings, the AC load consumption and indoor thermal comfort exacerbation in prefabricated offices is more serious. Especially in summer, a large amount of solar energy absorption from the roof raises the indoor air temperature and significantly increases the cooling load. This research contributes to the environmental design for prefabricated offices, and develops a method for the reuse of wood chips.
منابع مشابه
Energy Saving Analysis In Building Walls Through Thermal Insulation System
In this study, we discuss about the energy saving in different type of building walls by using optimum insulation thickness with suitable insulation material. The energy saving is maintained by reducing the energy consumption in buildings. Heat losses from building envelope have a major share in waste of energy. So it is essential to save the energy by using optimum insulation thickness. The in...
متن کاملImpacts of Building Insulation on Energy Consumption in Different Climates of Iran: A Cost Analysis
One of the most important energy-saving of building is suitable choice of insulation with regard to the climatic conditions of each region. In this study, the effects of building insulations approved by the Research Center of Way, Housing and Urban Development with regard to the cost of insulation on energy consumption in the region of Yazd, Tehran and Tabriz was evaluated by software Energy Pl...
متن کاملCarbon and Energy Footprints of Prefabricated Industrial Buildings: A Systematic Life Cycle Assessment Analysis
A systematic analysis of green-house gases emission (carbon footprint) and primary energy consumption (energy footprint) of prefabricated industrial buildings during their entire life cycle is presented. The life cycle assessment (LCA) study was performed in a cradle-to grave approach: site-specific data from an Italian company, directly involved in all the phases from raw material manufacturin...
متن کاملHeat Transfer, Environmental Benefits, and Social Cost Analysis of Different Insulation Methods by Considering Insulation Disadvantages
In this paper, the thermal performance of four common insulators in two internal and external insulation systems is investigated for the ASHRAE setpoint range by applying detailed numerical simulation and Anti-Insulation phenomenon. Anti-Insulation phenomenon and consequent extra load on the HVAC system can occur following the thermal insulation of a building if proper temperature setpoint is n...
متن کاملNovel Radon Sub-Slab Suctioning System
A new principle for radon protection is currently presented which makes use of a system of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground-floor slab. The function of this system is based on the principles of pressure reduction within the zone below the ground-floor construction. For this purpose a new system of prefabricated lightweigh...
متن کامل