Simultaneous Bilateral Implantation of Ex-Press Glaucoma Shunt for Secondary Glaucoma Treatment Due to Axenfeld-Rieger Syndrome: A Case Report

ثبت نشده
چکیده

Axenfeld-Rieger Syndrome (ARS) is a rare genetic disease affecting multiple organ systems. In the eye, it can be manifested with varying degrees of anterior segment dysgenesis and it carries a high risk of glaucoma [1]. Recent advantages in molecular genetics have identified two major genes, PITX2 and FOXC1, demonstrating a wide spectrum of mutations, which aids in the molecular diagnosis of the disease, although evidence exists to implicate other loci in this condition [2]. The management of individuals affected by Axenfeld-Rieger syndrome requires a multidisciplinary approach and would include dedicated surveillance and management of glaucoma, sensorineural hearing loss, and cardiac, endocrinological, craniofacial and orthopaedic abnormalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical experience with Ex-press Mini Glaucoma Shunt implantation.

In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 pati...

متن کامل

Axenfeld-Rieger Syndrome Associated with Congenital Glaucoma and Cytochrome P4501B1 Gene Mutations

Developmental anomalies of the ocular anterior chamber angle may lead to an incomplete development of the structures that form the conventional aqueous outflow pathway. Thus, disorders that present with such dysfunction tend to be associated with glaucoma. Among them, Axenfeld-Rieger (ARS) malformation is a rare clinical entity with an estimated prevalence of one in every 200,000 individuals. T...

متن کامل

Evaluation of Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma.

PURPOSE To evaluate the intraocular pressure (IOP) control and graft survival after Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma. METHODS The study included postpenetrating keratoplasty glaucoma cases unresponsive to medical antiglaucomatous therapy in whom 15 Ex-PRESS mini glaucoma shunt implantation was carried out. All glaucoma shunt implant...

متن کامل

OLOGEN® implant in the management of glaucoma in an unusual case of Axenfeld–Rieger syndrome

We report an unusual case of Axenfeld-Rieger Syndrome with secondary glaucoma managed with Ologen(®) implant. A 35-year-old male presented with complaints of decreased vision in both eyes of 22 years duration. His best corrected visual acuity (BCVA) was no perception of light in right eye and 20/30 in left eye. Gonioscopy revealed anterior insertion of iris into trabecular meshwork, prominent i...

متن کامل

Missed case of Axenfeld-Rieger syndrome: a case report

BACKGROUND Anterior segment dysgenesis is a failure of normal development of the anterior segment of the eye. The structural anomalies are associated with glaucoma and corneal opacity which may lead to blindness. CASE PRESENTATION A Caucasian male was noted to have 'funny pupils' at the age of seven years but not followed up. He was diagnosed to have Axenfeld-Rieger syndrome at the age of thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015