BACKGROUND Recent efforts have focused on reducing computed tomography (CT) imaging in children. Although published reports show variability in CT scanning for specific indications, an assessment of the effects of institutional factors (case-mix or hospital volume) on the rate of CT scanning for any indication is necessary to better understand variability across pediatric hospitals. METHODS Data from 2009 to 2013 on inpatient, observation, and emergency department (ED) encounters were extracted from the Pediatric Health Information System. Chronological trends and institutional variability in CT scan rates were examined by using negative binomial regression models. Case-mix was adjusted by using All Patient Refined Diagnosis Related Groups and severity level. RESULTS Thirty hospitals were included. There were 12 531 184 patient encounters and 701 644 CT scans resulting in a mean of 56 scans per 1000 encounters (range: 26-108). The most common scan types were head (60.1%) and abdomen/pelvis (19.9%). There was an inverse relationship between the CT scan rate and hospital volume (P = .002) and a direct relationship between the CT scan rates for inpatient/observation and ED encounters (P < .001). The rate of CT imaging decreased from 69.2 to 49.6 scans per 1000 encounters during the study period (P < .001). CONCLUSIONS The overall use of CT imaging is decreasing, and significant variability remains in CT use across tertiary pediatric hospitals. Hospital volume and institutional-level practices account for a significant portion of the variability. This finding suggests an opportunity for standardization through multi-institutional quality improvement projects to reduce CT imaging.
منابع مشابه
Computed Tomography and Shifts to Alternate Imaging Modalities in Hospitalized Children.
BACKGROUND Many studies have demonstrated a rise in computed tomography (CT) utilization in abstract children's hospitals. However, CT utilization may be declining, perhaps due to awareness of potential hazards of pediatric ionizing radiation, such as increased risk of malignancy. Th e objective is to assess the trend in CT utilization in hospitalized children at freestanding children's hospita...
متن کاملComputed tomography for minor head injury: variation and trends in major United States pediatric emergency departments.
OBJECTIVES To investigate the variation and trends in neuroimaging in children examined for minor head injury at major US pediatric emergency departments. STUDY DESIGN We conducted a retrospective study of children <19 years of age with mild head injury who were examined and discharged home from the emergency department at 40 pediatric hospitals from 2005 to 2009 by using the Pediatric Health...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملTrends in computed tomography utilization in the pediatric emergency department.
OBJECTIVE The purpose of this study was to determine the overall trend of computed tomography (CT) utilization in the pediatric emergency department (PED) from 2003 to 2010 and to determine trends categorized by common chief complaints. METHODS Electronic chart records at 2 tertiary care PEDs within a large pediatric health care system were reviewed from January 2003 through December 2010. Th...
متن کاملAssessment of Radiation Dose to the Lens of the Eye and Thyroid of Patients Undergoing Head and Neck Computed Tomography at Five Hospitals in Mashhad, Iran
Introduction: In recent years, the number of computed tomography (CT) scans, which is a high-dose technique, has increased significantly. Head and neck CT is performed frequently and thyroid, particularly in children, has always been considered a sensitive organ. In recent years, radiobiologists and health physicists have been more concerned about the safety of lenses of the eyes, as cataract i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pediatrics
دوره 136 5 شماره
صفحات -
تاریخ انتشار 2015