Detection of infective poliovirus by a simple, rapid, and sensitive flow cytometry method based on fluorescence resonance energy transfer technology.

نویسندگان

  • Jason L Cantera
  • Wilfred Chen
  • Marylynn V Yates
چکیده

The rapid and effective detection of virus infection is critical for clinical management and prevention of disease spread during an outbreak. Several methods have been developed for this purpose, of which classical serological and viral nucleic acid detection are the most common. We describe an alternative approach that utilizes engineered cells expressing fluorescent proteins undergoing fluorescence resonance energy transfer (FRET) upon cleavage by the viral 2A protease (2A(pro)) as an indication of infection. Quantification of the infectious-virus titers was resolved by using flow cytometry, and utility was demonstrated for the detection of poliovirus 1 (PV1) infection. Engineered buffalo green monkey kidney (BGMK) cells expressing the cyan fluorescent protein (CFP)-yellow fluorescent protein (YFP) substrate linked by a cleavage recognition site for PV1 2A(pro) were infected with different titers of PV1. After incubation at various time points, cells were harvested, washed, and subjected to flow cytometry analysis. The number of infected cells was determined by counting the number of cells with an increased CFP-to-YFP ratio. As early as 5 h postinfection, a significant number of infected cells (3%) was detected by flow cytometry, and cells infected with only 1 PFU were detected after 12 h postinfection. When applied to an environmental water sample spiked with PV1, the flow cytometry-based assay provided a level of sensitivity similar to that of the plaque assay for detecting and quantifying infectious virus particles. This approach, therefore, is more rapid than plaque assays and can be used to detect other viruses that frequently do not form clear plaques on cell cultures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier

Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...

متن کامل

Fluorescence resonance energy transfer-based HIV-1 virion fusion assay.

The fluorescence resonance energy transfer (FRET)-based HIV-1 virion fusion assay exploits the incorporation of beta-lactamase-Vpr chimeric proteins into HIV-1 virions and their subsequent delivery into the cytoplasm of target cells as a marker of fusion. This transfer can be monitored by the enzymatic cleavage of the CCF2-AM dye, a fluorescent substrate of beta-lactamase (BlaM), loaded into th...

متن کامل

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

Sensitive turn-on fluorescent detection of tartrazine based on fluorescence resonance energy transfer.

We introduce a sensitive, rapid, label-free and general fluorescent method for the determination of tartrazine by competitive binding to reduced graphene oxide (rGO) against fluorescein, and the fluorescence recovery upon fluorescein desorption from rGO provides a quantitative readout for tartrazine, giving a detection limit of 0.53 ng mL(-1).

متن کامل

Detection of frequency resonance energy transfer pair on double-labeled microsphere and Bacillus anthracis spores by flow cytometry.

Development of an ultrasensitive biosensor for biological hazards in the environment is a major need for pollutant control and for the detection of biological warfare. Fluorescence methods combined with immunodiagnostic methods are the most common. To minimize background noise, arising from the unspecific adsorption effect, we have adapted the FRET (frequency resonance energy transfer) effect t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 76 2  شماره 

صفحات  -

تاریخ انتشار 2010