Practical quantitative measurement of graticule misalignment relative to collimator axis of rotation

نویسندگان

  • Tarek Halabi
  • Bruce Faddegon
چکیده

We design a practical procedure for measuring translational and rotational misalignment of graticule with collimator axis of rotation and collimator jaws, respectively. The procedure's quantitative results are accurate to less than 0.2 mm (at isocenter) and do not assume alignment of radiation focal spot with collimator axis of rotation. When provided with these quantitative results, the manufacturer can custom-adjust graticules to the purchaser's collimator head.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Method for Quality Assurance of the Cyberknife Iris Variable Aperture Collimator

OBJECTIVE To characterize a novel method for field-size quality assurance of a variable approximately circular aperture collimator by means of dose-area product measurements and to validate its practical use over two years of clinical application. METHODS   To assess methodical limitations, we analyze measurement errors due to change in linac output, beam tuning, uncertainty in MU delivery, d...

متن کامل

Effect of Head Misalignment in Horizontal & Vertical Dimensions on the Magnification Rate of Digital Panoramic Radiography in Different Parts of the Jaws

Background and aim: Considering the widespread development of implants in dental treatment plans, linear measurements on panoramic radiography are of especial importance. In the present study we investigated the effect of head misalignment up to 15° around vertical and horizontal axes on the magnification rate of digital panoramic radiography in each part of upper and lower jaws. Materia...

متن کامل

P 230 Endothelial response and bloo-aqueous barrier breakdown following phacoemulsification

MEASUREMENT OF CORNEAL AND CRYSTALLINE LENS MISALIGNMENT RELATIVE TO THE VISUAL AXIS DUNNE M.C.M.1, BARRY J.C.2, HARTMANN A.2, CULPIN F.1, DE MAIN J.l, DUKE A.1 and FRENCH 1.1 I Department of Vision Sciences, Aston University (UK) 2 Department of Ophthalmology, RUTH Aachen (Germany) %rpare To measure the misalignment between the comeal and crystalline lens axes relative to the visual axis. To e...

متن کامل

P 227 Measurement of corneal and crystalline lens misalignment relative to the visual axis

MEASUREMENT OF CORNEAL AND CRYSTALLINE LENS MISALIGNMENT RELATIVE TO THE VISUAL AXIS DUNNE M.C.M.1, BARRY J.C.2, HARTMANN A.2, CULPIN F.1, DE MAIN J.l, DUKE A.1 and FRENCH 1.1 I Department of Vision Sciences, Aston University (UK) 2 Department of Ophthalmology, RUTH Aachen (Germany) %rpare To measure the misalignment between the comeal and crystalline lens axes relative to the visual axis. To e...

متن کامل

Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application.

PURPOSE For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010