Donor Safety in Haemapheresis: Development of an Internet-Based Registry for Comprehensive Assessment of Adverse Events from Healthy Donors.

نویسندگان

  • Hans-Gert Heuft
  • Eike Fischer
  • Tina Weingand
  • Thomas Burkhardt
  • Gerda Leitner
  • Hagen Baume
  • Jörg-Peter Schmidt
  • Andreas Buser
  • Gabriele Fauchald
  • Ute Reinicke Voigt
  • Behrouz Mansouri-Taleghani
چکیده

BACKGROUND Currently, there is an extensive but highly inconsistent body of literature regarding donor adverse events (AEs) in haemapheresis. As the reports diverge with respect to types and grading of AEs, apheresis procedures and machines, the range of haemapheresis-related AEs varies widely from about 0.03% to 6.6%. METHODS The German Society for Transfusion Medicine and Immunohaematology (DGTI) formed a 'Haemapheresis Vigilance Working Party' (Arbeitsgemeinschaft Hämapheresevigilanz; AGHV) to create an on-line registry for comprehensive and comparable AE assessment with all available apheresis devices in all types of preparative haemapheresis: plasmapheresis (PLS), plateletpheresis (PLT), red blood cell apheresis, all kind of leukaphereses (autologous/allogeneic blood stem cell apheresis, granulocyte apheresis, lymphocyte/monocyte apheresis) and all possible types of multi-component apheresis. To ensure the comparability of the data, the AGHV adopted the 'Standard for Surveillance of Complications Related to Blood Donation' from the International Society for Blood Transfusion in cooperation with the International Haemovigilance Network (IHN) and the American Association of Blood Banks for AE acquisition and automated evaluation. The registry is embedded in a prospective observational multi-centre study with a study period of 7 years. RESULTS A preliminary evaluation encompassed the time period from January, 2012 to December, 2015. During this time, the system proved to be safe and stable. Out of approximately 345,000 haemaphereses 16,477 AEs were reported (4.9%) from 20 participating centres. The majority of AEs occurred in PLSs (63%), followed by PLT (34.5%) and SC (2.2%). Blood access injuries (BAI) accounted for about 55% of the supplied AEs, whereas citrate toxicity symptoms, vasovagal reactions and technical events (e.g. disposable leakages, software failures) rather equally affected haemaphereses at 8-15%. Out of 12,348 finalized AEs, 8,759 (70.1%) were associated with a procedure-related break-off, with BAI being the prevailing cause (5,463/8,759; 62.4%). An automated centre- and procedure-specific AE evaluation according to the latest IHN standard and AGHV pre-settings is available within a few minutes. CONCLUSIONS An on-line electronic platform for comprehensive assessment and centre-specific automated evaluation of AEs in haemaphereses has been developed and proved to be stable and safe over a period of 4 years.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Allele Frequencies of HLA-A, B and DRB1 among People of Fars Ethnicity Living in Tehran

Background: Human leukocyte antigens (HLA) are polymorphic cell surface proteins. Distribution of HLA alleles vary among different racial and ethnic populations in unrelated stem cell registries. Determination of HLA allele frequencies in different ethnic groups is useful for population genetic analyses. Materials and Methods: Based on data available from the Iranian Stem Cell Donor Registry...

متن کامل

P-144: Egg and Embryo Donor's Application Forms in Infertility Centers; Medical, Genetic and Psychosocially Forms in Evaluating Potential Donor Candidate

Background: Nowadays, gamete and embryo donation is applied as effective process in treatment infertility problems. In order to participate in the process of donation, donors should complete an extensive questionnaire that details their personal and family medical history. Included in this questionnaire should be a detailed sexual history, substance abuse history, history of family disease, and...

متن کامل

A Safe and Sustainable Development in a Hygiene and Healthy Company Using Decision Matrix Risk Assessment Technique: a case study

This article describes the process of improving risk management practices in a foundry of the ALFET Company (Algeria). The proposed methodology is based on the decision matrix risk assessment technique. This technique allows making a risk assessment for each source of risk (machine, man, environment, and management), which leads to the determination of the overall risk rate during the activity ...

متن کامل

The referral frequency of blood donors positive in HIV, HBV, and HCV screening tests after being called for and reasons for their non-return

                                     Abstract Background and Objectives Informing and counseling donors with positive Transfusion Transmitted Infection (TTI) is essential for preventing them from donating blood in future, and starting treatment for reducing complications. So, we evaluated the referral of reactive donors.   Materials and Methods This cross sectional study was conducted in Sh...

متن کامل

Comparing frequency of injecting drug use among accepted HCV infected blood donors in different regions of Iran

Abstract Background and Objectives Considering the importance of donor selection process in blood safety, this study aimed at comparison of frequency of intravenous drug use (IDU) among accepted HCV positive blood donors in different regions of Iran.   Materials and Methods This cross sectional-analytical study was conducted on  serologically confirmed HCV positive blood donors who referred ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2017