Deformable Templates for the Localization of Anatomical Structures in Radiologic Images
نویسندگان
چکیده
This paper describes a method for non-rigid registration of a model template with the corresponding anatomic structure in a radiologic image. The model template is a graph consisting of labeled nodes and edges. Each node is labeled by a feature vector that characterizes the sought structures in its vicinity. The edges connect the nodes in accordance with anatomical topology. The features which describe possible node positions are computed by ltering the image with a set of Gabor lters and comparing the lter responses with those from the model. The nal node positions are determined by minimizing a deformation energy term associated with the template. We show results for digitized lm orthopantomograms of the jaw which indicate good performance at modest computational e ort for such artifact-rich images. The results are used for localization of bone lesions relative to anatomic structures.
منابع مشابه
Medical Image Segmentation and Localization using Deformable Templates
This paper presents deformable templates as a tool for segmentation and localization of biological structures in medical images. Structures are represented by a prototype template, combined with a parametric warp mapping used to deform the original shape. The localization procedure is achieved using a multi-stage, multi-resolution algorithm designed to reduce computational complexity and time. ...
متن کاملComparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei
Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...
متن کاملA feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...
متن کاملQuality enhancement of Pelvis electronic portal images in order to improve treatment accuracy
Introduction: In order to reduce patient setup error in treatment field, portal images with treatment beam (megavoltage x-ray) are widely used. These images are acquired by electronic portal imaging devices (EPID). However, portal images suffer from insufficient anatomical information, contrast, and spatial resolution, because of the fact that Compton scatter is the main photon...
متن کاملDeformable Templates for the Localization
This paper describes a method for non-rigid registration of a model template with the corresponding anatomic structure in a radi-ologic image. The model template is a graph consisting of labeled nodes and edges. Each node is labeled by a feature vector that characterizes the sought structures in its vicinity. The edges connect the nodes in accordance with anatomical topology. The features which...
متن کامل