Biological effect on drug distribution and vascular healing via paclitaxel‐coated balloon technology in drug eluting stent restenosis swine model

نویسندگان

  • Yan Li
  • Armando Tellez
  • Serge D. Rousselle
  • Krista N. Dillon
  • Javier A. Garza
  • Chris Barry
  • Juan F. Granada
چکیده

OBJECTIVES To evaluate the biological effect of a paclitaxel-coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES-ISR) swine model. BACKGROUND The mechanism of action and healing response via PCB technology in DES-ISR is not completely understood. METHODS A total of 27 bare metal stents were implanted in coronary arteries and 30 days later the in-stent restenosis was treated with PCB. Treated segments were harvested at 1 hr, 14 days and 30 days post treatment for the pharmacokinetic analysis. In addition, 24 DES were implanted in coronary arteries for 30 days, then all DES-ISRs were treated with either PCB (n = 12) or uncoated balloon (n = 12). At day 60, vessels were harvested for histology following angiography and optical coherence tomography (OCT). RESULTS The paclitaxel level in neointimal tissue was about 18 times higher (P = 0.0004) at 1 hr Cmax , and retained about five times higher (P = 0.008) at day 60 than that in vessel wall. A homogenous distribution of paclitaxel in ISR was demonstrated by using fluorescently labeled paclitaxel. Notably, in DES-ISR, both termination OCT and quantitative coronary angioplasty showed a significant neointimal reduction and less late lumen loss (P = 0.05 and P = 0.03, respectively) post PCB versus post uncoated balloon. The PES-ISR + PCB group displayed higher levels of peri-strut inflammation and fibrin scores compared to the -limus DES-ISR + PCB group. CONCLUSIONS In ISR, paclitaxel is primarily deposited in neointimal tissue and effectively retained over time following PCB use. Despite the presence of metallic struts, a uniform distribution was characterized. PCB demonstrated an equivalent biological effect in DES-ISR without significantly increasing inflammation. © 2015 Wiley Periodicals, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy of different paclitaxel-eluting balloons in a porcine model.

INTRODUCTION AND OBJECTIVES Paclitaxel-eluting balloons have shown high antiproliferative efficacy in the treatment and prevention of restenosis. Nevertheless, not all available devices are equally effective, which makes it interesting to compare results in a preclinical model. Our objective was to assess the preclinical efficacy and safety of different devices. METHODS We implanted 51 metall...

متن کامل

Letter by Alfonso et al regarding article, "Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis".

BACKGROUND Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. METHODS AND RESULTS One hun...

متن کامل

Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent Restenosis

Background—Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. Methods and Results—One hundr...

متن کامل

No-Reflow Phenomenon During Treatment of Coronary In-Stent Restenosis With a Paclitaxel-Coated Balloon Catheter

Drug-eluting balloon (DEB) with angioplasty a paclitaxel-coated balloon catheter is an effective treatment option in patients with in-stent restenosis (ISR) after a drug-eluting stent (DES). We describe a case in which 'no-reflow' phenomenon developed after DEB angioplasty of a DES ISR lesion. Coronary flow was restored after intracoronary administration of nicorandil.

متن کامل

Safety and efficacy of a novel iopromide-based paclitaxel-eluting balloon following bare metal stent implantation in rabbit aorta abdominalis

BACKGROUND Drug-eluting balloons (DEB) may be promising technology for treating atherosclerotic arterial disease. In fact, several DEBs have been clinically available for the treatment of coronary in-stent restenosis (ISR), de novo coronary lesions, and peripheral artery disease. OBJECTIVE We sought to elucidate the mechanism of action and in vivo safety and efficacy of a novel iopromide-base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 88  شماره 

صفحات  -

تاریخ انتشار 2016