MGGPOD: a Monte Carlo Suite for Modeling Instrumental Line and Continuum Backgrounds in Gamma-Ray Astronomy

نویسندگان

  • G. Weidenspointner
  • M. J. Harris
  • S. Sturner
  • B. J. Teegarden
  • C. Ferguson
چکیده

Intense and complex instrumental backgrounds, against which the much smaller signals from celestial sources have to be discerned, are a notorious problem for low and intermediate energy γ-ray astronomy (∼ 50 keV – 10 MeV). Therefore a detailed qualitative and quantitative understanding of instrumental line and continuum backgrounds is crucial for most stages of γ-ray astronomy missions, ranging from the design and development of new instrumentation through performance prediction to data reduction. We have developed MGGPOD, a userfriendly suite of Monte Carlo codes built around the widely used GEANT (Version 3.21) package, to simulate ab initio the physical processes relevant for the production of instrumental backgrounds. These include the build-up and delayed decay of radioactive isotopes as well as the prompt de-excitation of excited nuclei, both of which give rise to a plethora of instrumental γ-ray background lines in addition to continuum backgrounds. The MGGPOD package and documentation are publicly available for download from http://sigma-2.cesr.fr/spi/MGGPOD/. We demonstrate the capabilities of the MGGPOD suite by modeling high resolution γ-ray spectra recorded by the Transient Gamma-Ray Spectrometer (TGRS) on board Wind during 1995. The TGRS is a Ge spectrometer operating Universities Space Research Association, 7501 Forbes Blvd., Seabrook, MD 20706-2253, USA Centre d’Etude Spatiale des Rayonnements, 9 Avenue Colonel Roche, 31028 Toulouse Cedex 4, France

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 07 02 62 3 v 1 2 3 Fe b 20 07 MGGPOD : A MONTE CARLO SUITE FOR GAMMA RAY ASTRONOMY – VERSION 1 . 1

We announce the forthcoming public release of Version 1.1 of MGGPOD, a user-friendly suite of Monte Carlo codes built around the widely used GEANT (Version 3.21) package. MGGPOD is capable of simulating ab initio the physical processes relevant for the production of instrumental backgrounds. These processes include the build-up and delayed decay of radioactive isotopes as well as the prompt de-...

متن کامل

Monte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models

Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...

متن کامل

Considerations for the Next Compton Telescope Mission

A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffu...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004