Transesophageal versus intracoronary Doppler measurements for calculation of coronary flow reserve.

نویسندگان

  • M Zehetgruber
  • G Porenta
  • G Mundigler
  • D Mörtl
  • T Binder
  • G Christ
  • P Probst
  • H Baumgartner
  • G Maurer
  • P Siostrzonek
چکیده

OBJECTIVE The present study was performed to compare coronary flow reserve by transesophageal Doppler echocardiography and intracoronary Doppler flow wire measurements in patients with LAD disease. METHODS 17 patients with various degree of LAD stenosis were studied. Intracoronary LAD Doppler measurements were performed at baseline and after intracoronary injection of 18 micrograms adenosine. Transesophageal coronary sinus and LAD Doppler measurements were performed at baseline and after intravenous dipyridamole (0.6 mg/kg/5 min). Coronary flow reserve was calculated as the ratio of hyperemic to baseline average peak velocities. RESULTS Coronary flow reserve was 2.44 +/- 0.62 and 2.19 +/- 0.76 for proximal and distal intracoronary measurements and was 2.25 +/- 0.64 and 1.74 +/- 0.63 for transesophageal LAD- and coronary sinus measurements. Proximal intracoronary flow reserve significantly correlated with transesophageal coronary sinus (r = 0.73, p < or = 0.001) and LAD (r = 0.70, p < or = 0.005) measurements, whereas distal intracoronary flow reserve only correlated with transesophageal coronary sinus flow reserve (r = 0.56, p < or = 0.02). Receiver operating characteristic curve analysis demonstrated similar diagnostic accuracy of all applied techniques for detection of a significant LAD stenosis. CONCLUSIONS Coronary flow reserve by both transesophageal techniques correlated with intracoronary Doppler flow wire measurements, however considerable discrepancies may occur in the individual patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of coronary flow reserve by transesophageal coronary sinus Doppler measurements in patients with syndrome X and patients with significant left coronary artery disease.

OBJECTIVES This study sought to determine the feasibility of coronary sinus flow velocity analysis by transesophageal Doppler echocardiography for estimation of coronary flow reserve in patients with syndrome X and patients with coronary artery disease. BACKGROUND Coronary flow reserve provides useful information in patients with coronary artery disease and patients with syndrome X. Current m...

متن کامل

Myocardial bridging in a survivor of sudden cardiac near-death: role of intracoronary doppler flow measurements and angiography during dobutamine stress in the clinical evaluation.

Extensive myocardial bridging in the left anterior descending coronary artery was found in a 46 year old survivor of sudden cardiac near-death. Positron emission tomography and dobutamine stress echocardiography revealed ischaemia in the myocardium distal to the bridging. Spasm was excluded as cause of the ischaemia by intracoronary infusion of acetylcholine. Further evaluation of the haemodyna...

متن کامل

Effects of Intravenous and Intracoronary Adenosine 5*-Triphosphate as Compared With Adenosine on Coronary Flow and Pressure Dynamics

Background—Measurements of Doppler derived coronary flow reserve (CFR) and pressure derived fractional flow reserve (FFR) for coronary stenosis assessment depend on the induction of maximal hyperemia. Adenosine is the most widely used pharmacological agent but is expensive and poorly tolerated by some patients. Methods and Results—The objective of this study was to test the equivalency of adeno...

متن کامل

Effects of intravenous and intracoronary adenosine 5'-triphosphate as compared with adenosine on coronary flow and pressure dynamics.

BACKGROUND Measurements of Doppler derived coronary flow reserve (CFR) and pressure derived fractional flow reserve (FFR) for coronary stenosis assessment depend on the induction of maximal hyperemia. Adenosine is the most widely used pharmacological agent but is expensive and poorly tolerated by some patients. METHODS AND RESULTS The objective of this study was to test the equivalency of ade...

متن کامل

Which Variable of Stenosis Severity Best Describes the Significance of an Isolated Left Anterior Descending Coronary Artery Lesion?

Objectives. This study sought to investigate the angiographic or intracoronary Doppler variables of stenosis severity that best correlate with the results of dipyridamole echocardiography. Background. Quantitative coronary angiography and intracoronary Doppler flow velocity assessments are the commonly used techniques for the objective identification of significant coronary artery stenosis. Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular research

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 1997