Implantable collamer lens for high myopia: assessment of visual quality after implantation

نویسندگان

  • Ying Tian
  • Xiaobo Xia
  • Weitao Song
  • Jian Jiang
  • Haibo Jiang
  • Endong Zhang
چکیده

Background: Patients with high myopia have higher risk of eye diseases. Currently, Implantable collamer lens (ICL) implantation is one of the widely used refractive intraocular lens surgical intervention methods. Purpose: To evaluate the effectiveness of implantable collamer lens (ICL) implantation in high myopia patients and the changes in wavefront aberrations after the operation. Methods: Thirty-two eyes with high myopia were enrolled. The spherical equivalent, visual acuity including near vision, uncorrected distant visual acuity (UDVA) and corrected distant visual acuity (CDVA), and the total aberrations root mean square (Total-RMS) were measured before and after ICL operation. Furthermore, Total-RMS fixating on targets at 2 distances (5 m and 30 cm) was compared. Results: One month after ICL implantation, UDVA and CDVA were increased (P<0.05). The average spherical equivalent, entire eye Total-RMS and internal optics Total-RMS were decreased (P<0.05). Furthermore, Total-RMS of entire eye and internal optics were lower with fixating on 5m distance target than with 30cm distance target at three postoperative time points. 6-month after ICL operation, total LOA-RMS and total HOA-RMS fixating on targets at 2 distances were different (P<0.001 and P=0.026, respectively). Moreover, compensation effect of internal optics aberrations on corneal aberrations was better with fixating on 5 m distance target than with 30 cm distance target (P=0.002). Conclusions: After ICL implantation, high myopia patients have significant improvement of visual acuity. Furthermore, wavefront aberrations of distant vision are obviously lower than that of near vision after ICL implantation in high myopia patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia

The aim of this study was to investigate the visual quality of the 2 kinds of intraocular lens: Visian implantable collamer lens (ICL) V4 and Visian ICL V4c implantations for high myopia.Twenty cases (20 eyes) with high myopia who received Visian ICL V4 implantation and 18 cases (18 eyes) with high myopia who received Visian ICL V4c implantation in our hospital from April 1, 2014 to November 31...

متن کامل

Visual outcomes and patient satisfaction after implantable collamer lens and Toric implantable collamer lens correction for moderate to high myopia and myopic astigmatism.

OBJECTIVE To compare preoperative and postoperative visual outcomes, determine patient's satisfaction, and evaluate visual symptoms after implantable collamer lens (ICL) implantation. METHODS One hundred and twelve patients with myopia between -2.75 and -19.50 diopter had ICL or Toric ICL (TICL) implantation. The implantations were carried out at the Cornea and Refractive Unit, Magrabi Eye Ho...

متن کامل

Evaluation of Phakic Posterior Chamber Intraocular Implantable Contact Lens for High Myopia

Purpose: To evaluate efficacy, predictability and safety of the surgical correction of high myopia using the phakic posterior chamber implantable collamer lens. Design: A prospective, nonrandomized, non-comparative interventional case series. Participants: Twenty seven eyes of fifteen patients aged from 20 to 46 years having high myopia were included. Intervention: STAAR modified collamer impla...

متن کامل

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator Lente implantável de collamer e laser de femtosegundo para miopia: comparação usando um simulador visual de óptica adaptativa

The femtosecond laser (FS) is the most interesting technical de velopment in laser refractive surgery during the last few years. This technique was developed to create flaps for laser in situ keratomileusis (LASIK). The FS is a focusable infrared (1053 nm) laser that uses ultrafast pulses in the 100-femtosecond (100 x 10 second) range. The laser delivers closely spaced spots that can be focused...

متن کامل

Stability of axis and patient satisfaction after toric implantable collamer lens implantation for myopic astigmatism

OBJECTIVES To assess the stability of axis and patient satisfaction after toric visian implantable collamer lens (TICL) implantation for moderate to high myopic astigmatism. METHODS Total 33 eyes of 21 consecutive patients who underwent implantation of TICL for the correction of moderate to high myopic astigmatism were recorded and a minimum follow-up of six months was performed. The deviatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016