BiliCheck transcutaneous bilirubinometer: a screening tool for neonatal jaundice in the Chinese population.
نویسندگان
چکیده
OBJECTIVE To verify the usefulness of the BiliCheck transcutaneous bilirubin meter as a screening device for neonatal jaundice in a Chinese population compared with the Minolta bilirubin meter. DESIGN A prospective correlation study that compared transcutaneous bilirubin measurements with serum bilirubin levels. SETTING Obstetric ward and a neonatal unit of a regional hospital in Hong Kong. PATIENTS Neonates with gestation above 32 weeks with neonatal jaundice who were admitted between April 2001 and February 2002. MAIN OUTCOME MEASURES Transcutaneous measurements of serum bilirubin obtained from the forehead and the sternum with two instruments: BiliCheck and Minolta Airshields JM 102. RESULTS A total of 77 term and six near-term babies (gestation, 32-37 weeks) were recruited. The mean age at the time of data collection was 3.96 days (range, 2-9 days). The correlations between serum bilirubin and transcutaneous bilirubin measurements of the two devices at the two sites were high, with a coefficient of 0.718 (95% confidence interval, 0.610-0.800; n=100) for forehead measurements, and 0.814 (95% confidence interval, 0.740-0.870; n=99) for sternum using the Minolta Airshields JM 102; and a coefficient of 0.757 (95% confidence interval, 0.657-0.827; n=98) for forehead measurements, and 0.794 (95% confidence interval, 0.700-0.862; n=92) for sternum using the BiliCheck. For BiliCheck, a cut-off point of 250 micromol/L at the forehead and 260 micromol/L at the sternum had a specificity of 61.9% and 70.0%, respectively with a sensitivity of 100% for the detection of serum bilirubin concentrations of 250 micromol/L or higher. This level is commonly used as the level for initiation of treatment such as phototherapy. CONCLUSION BiliCheck is a useful screening tool for neonatal jaundice in the Chinese population and is comparable with the Minolta Airshields JM 102.
منابع مشابه
The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran
The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...
متن کاملThe Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran
The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...
متن کاملAccuracy of transcutaneous bilirubinometer estimates using BiliCheck in Thai neonates.
BACKGROUND Neonatal jaundice is the most frequently encountered diagnostic and therapeutic problem in the newborn. In the jaundiced infant, it is thought that the binding capacity of plasma albumin is exceeded, which allows free bilirubin to diffuse into and accumulate within extravascular tissues, such as the central nervous system. Affected newborns may develop kernicterus. The standard metho...
متن کاملMeasurement of Transcutaneous Bilirubin with Bilicheck as a Jaundice Screening Method in Neonates in Pediatric Emergency Departments
Objectives: To study the reliability of a transcutaneous bilirubinometer (Bilicheck) to determine bilirubin levels in neonates consulting for jaundice in a Paediatric Emergency Department (ED), and to evaluate its usefulness as a screening method. Methods: Prospective observational study realized between June of 2005 and December of 2005 in neonates consulting at a paediatric emergency departme...
متن کاملTrans-Cutaneous Bilirubinometery versus Serum Bilirubin in Neonatal Jaundice.
Hyperbilirubinemia is a common problem in neonates and causes serious complications. Thus, serial measurements of bilirubin should be done. This assessment is done through two methods of laboratory measurement in serum sample and transcutaneous bilirubinometer. This descriptive study compared transcutaneous bilirubin assessment and laboratory serum bilirubin. Bilirubin level was assessed among ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hong Kong medical journal = Xianggang yi xue za zhi
دوره 12 2 شماره
صفحات -
تاریخ انتشار 2006