Disc embolisation after minor strut fracture in a Björk-Shiley mitral valve prosthesis.
نویسندگان
چکیده
We report the successful management of a patient who suffered embolisation of a Bjork-Shiley mitral prosthetic valve disc after fracture of the minor strut. Emergency surgical treatment was responsible for her survival. The disc was recovered through the abdominal aorta at a subsequent operation, performed once the condition of the patient had stabilised. This experience confirms previous reports' 2 advocating early reoperation in patients with Bjork-Shiley prostheses who present with acute heart failure and absence of prosthetic valve sounds. We suggest that retrieval of the embolised disc may be carried out separately as an elective procedure provided that there is no evidence of renal or peripheral circulatory impairment.
منابع مشابه
Unusual Disc Dislodgement of a Björk-Shiley Valve after Long-term Implantation
https://e-kcj.org A 40-year-old male was admitted to the cardiac care unit (CCU) due to severe pneumonia associated with unstable hemodynamics. Meanwhile, a grade 3–4 systolic murmur was heard at the left lower sternal border. Tracing his history back, he had undergone mitral valve replacement with a Björk-Shiley convexoconcave prosthetic valve (single tilting disc mechanical valve) 25 years be...
متن کاملPsychological distress among recipients of Björk-Shiley convexo-concave valves: the impact of information.
OBJECTIVE To establish whether there is more psychological distress among recipients of Björk-Shiley convexo-concave (BScc) valves than among recipients of other valves not known to fracture. DESIGN Cross sectional study. PATIENTS 137 patients who received either a BScc valve or a Sorin Biomedical spherical valve during a randomised trial between 1982 and 1983 at St Antonius Hospital, Nieuw...
متن کاملHaemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis.
The present study reports on the incidence and degree of intravascular haemolysis in 33 patients with Björk-Shiley tilting disc prosthesis and in 34 patients with Lillehei-Kaster pivoting disc valve prosthesis in the mitral position examined 12 to 24 months after the operation. Serum haptoglobin, serum lactate dehydrogenase, serum bilirubin, and haemoglobin estimations were performed. Significa...
متن کاملMetallurgical analysis of failed Björk-Shiley cardiac valve prostheses.
An investigation into the mechanisms of failure of current Björk-Shiley cardiac valve prostheses is reported. Two failed valves, one apparently unfailed but defective valve, and one unused valve, were examined by scanning electron microscopy and metallographic section. In the first two valves (removed 12 and 23 months after implantation) fracture was associated with the welds joining the short ...
متن کاملDoppler and two-dimensional echocardiographic diagnosis of Björk-Shiley prosthetic valve malfunction: importance of interventricular septal motion and the timing of onset of valve flow.
In a 69 year old woman with a "sticking" Björk-Shiley mitral prosthesis, the diagnosis was suggested by both the two-dimensional and the Doppler ultrasound examinations. In particular, the findings of early diastolic paradoxic septal motion, intermittent delayed opening of the prosthetic disc and variable timing of the onset of mitral valve inflow were believed to be diagnostic of a sticking ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 38 5 شماره
صفحات -
تاریخ انتشار 1983