Atomic Absorption Spectrometry in Wilson's Disease and Its Comparison with Other Laboratory Tests and Paraclinical Findings
نویسندگان
چکیده
OBJECTIVE Wilson's disease (WD) is an autosomal recessive disease with genetic abnormality on chromosome 13 causing defect in copper metabolism and increased copper concentration in liver, central nervous system and other organs, which causes different clinical manifestations. The aim of this study was to determine the sensitivity of different clinical and paraclinical tests for diagnosis of Wilson's disease. METHODS Paraffin blocks of liver biopsy from 41 children suspicious of WD were collected. Hepatic copper concentrations were examined with atomic absorption spectrophotometry (Australian GBC, model: PAL 3000). Fifteen specimens had hepatic copper concentration (dry weight) more than 250μg/g. Clinical and laboratory data and histologic slides of liver biopsies of these 15 children were reviewed retrospectively. Liver tissue was examined for staging and grading of hepatic involvement and also stained with rubeonic acid method for copper. FINDINGS Patients were 5-15 years old (mean age=9.3 years, standard deviation=2.6) with slight male predominance (9/15=60%). Five (33%) patients were 10 years old. Three (20%) of them were referred for icterus, 8 (54%) because of positive family history, 2 (13%) due to abdominal pain and 2 (13%) because of hepatosplenomegaly and ascites. Serum AST and ALT levels were elevated at the time of presentation in all patients. In liver biopsy, histological grade and stage was 0-8 and 0-6 respectively, 2 (13%) had cirrhosis, 1 (7%) had normal biopsy and 12 (80%) showed chronic hepatitis. Hepatic copper concentrations were between 250 and 1595 μg/g dry weight. The sensitivity of various tests were 85% for serum copper, 83% for serum ceruloplasmin, 53% for urinary copper excretion, 44% for presence of KF ring and 40% for rubeonic acid staining on liver biopsies. CONCLUSION None of the tests stated in the article were highly sensitive for diagnosis of WD, so we suggest that diagnosis should be based on combination of family history, physical examination and different tests.
منابع مشابه
Comparison of Common Paraclinical Tests' Results in Semnan Province with the Global Reference Ranges: a Cross Sectional Study with High Sample Size
Abstract Background and Objective: Knowledge about normal range of tests is one of the most important parameters in correct interpretation of the results. Accordingly, we decided to determine normal range of common paraclinical tests in Semnan and compare them with global reference ranges. Material and Methods: The data from Khatam-al-Anbia laboratory from year 2011 to 2013 ev...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملEVALUATION OF LABORATORY FINDINGS IN CHILDREN WITH WILSON\'S DISEASE IN EMA M KHOMEINI HOSPITAL DURING 1994-2003
Wilson's disease is a rare but treatable condition with variable clinical presentations. Its diagnosis depends on a combination of clinical and laboratory findings. We evaluated the clinical and laboratory findings in children with Wilson's disease (WD). Twenty -seven children (4-14 years, 59.2 % male, 40.7% female) with confirmed WD were evaluated between 1994 and 2003 at Imam Khomeini Hos...
متن کاملThe role of laboratory findings in the diagnosis, treatment and prognosis of bronchiolitis
Abstract Background: Acute bronchiolitis is the most common cause of lower respiratory tract infection and hospitalization due to respiratory disease during infancy. The disease is mainly diagnosed based on history and clinical examination, with paraclinical investigation being of little value in the diagnosis. The present study aimed to determine the role of paraclinical tests in the managemen...
متن کاملDetermination of serum lithium: comparison between atomic emission and absorption spectrometry methods
Introduction: The therapeutic monitoring of lithium, through concentration measurements, is important for individual dose adjustment, as a marker of treatment adherence and to prevent poisoning and side effects. Objectives: Validate and compare two methods – atomic emission and atomic absorption – for the determination of lithium in serum samples. Methodology: Parameters such as specificity, pr...