The effect of the arthroscopic augmentation of the subscapularis tendon on shoulder instability and range of motion: A biomechanical study.
نویسندگان
چکیده
BACKGROUND Anterior shoulder dislocation is common. The treatment of recurrence with glenoid bone defect is still considered controversial. A new arthroscopic subscapularis augmentation has recently been described that functions to decrease the anterior translation of the humeral head. The purpose of the presented study was to examine the biomechanical effect on glenohumeral joint motion and stability. METHODS Eight fresh frozen cadaver shoulders were studied by use of a force guided industrial robot fitted with a six-component force-moment sensor to which the humerus was attached. The testing protocol includes measurement of glenohumeral translation in the anterior, anterior-inferior and inferior directions at 0°, 30° and 60° of glenohumeral abduction, respectively, with a passive humerus load of 30N in the testing direction. The maximum possible external rotation was measured at each abduction angle applying a moment of 1Nm. Each specimen was measured in a physiologic state, as well as after Bankart lesion with an anterior bone defect of 15-20% of the glenoid, after arthroscopic subscapularis augmentation and after Bankart repair. FINDINGS The arthroscopic subscapularis augmentation decreased the anterior and anterior-inferior translation. The Bankart repair did not restore the mechanical stability compared to the physiologic shoulder group. External rotation was decreased after arthroscopic subscapularis augmentation compared to the physiologic state, however, the limitation of external rotation was decreased at 60° abduction. INTERPRETATION The arthroscopic subscapularis augmentation investigated herein was observed to restore shoulder stability in an experimental model.
منابع مشابه
Interstitial Tear of the Subscapularis Tendon, Arthroscopic Findings and Technique of Repair
Tears of the subscapularis tendon have been significantly recognized as a source of shoulder pain and dysfunction in the past decade, thanks to arthroscopic evaluation of the shoulder and biomechanical and anatomical studies of the tendon. Current classification of subscapularis tendon tear is based on insertion site of the tendon. Recently, a classification for non-insertional types of subsc...
متن کاملShort term results of arthroscopic repair of subscapularis tendon tear
Abstract Background: Despite being the largest rotator cuff tendon of the shoulder, the function and clinical relevance of subscapularis pathology has been largely ignored in the literature. Although many studies have focused on subscapularis tears recently, majority of them reported techniques for open repair. The advent of arthroscopy and arthroscopic repair techniques has opened ...
متن کاملEarly Clinical Results of Arthroscopic Remplissages in Patients with Anterior Shoulder Instability with Engaging Hill-Sachs Lesion in Iran
Background: To assess the outcome of the remplissage arthroscopic surgical method in patients with anterior shoulder dislocation associated with Hill-Sachs lesion. Methods: Ten patients with anterior shoulder dislocations and Hill-Sachs lesions were entered into this study and were operated on by the remplissage arthroscopic surgical method. They were followed up 22 months after surgery...
متن کاملINTERSTITIAL TEAR OF THE SUBSCAPULARIS TENDON, ARTHROSCOPIC FINDINGS AND TECHNIQUE OF REPAIR
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملAssessment of Correlation Between MRI and Arthroscopic Pathologic Findings in the Shoulder Joint
Background: The objective of this study was to determine the diagnostic value of magnetic resonance imaging for shoulder joint pathologies and then compare the results with arthroscopy, the standard for joint diagnosis. Methods: In this cross-sectional study, 80 patients with shoulder joint disorders, who underwent final arthroscopy, were studied. Based on patients’ medical history and physic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biomechanics
دوره 38 شماره
صفحات -
تاریخ انتشار 2016