The impact of bowl size, program setup, and blood hematocrit on the performance of a discontinuous autotransfusion system.

نویسندگان

  • Timo F Seyfried
  • Michael Gruber
  • Fabian Streithoff
  • Robert J Mandle
  • Michael T Pawlik
  • Hendrik Busse
  • Ernil Hansen
چکیده

BACKGROUND Cell salvage is an essential element in the concept of blood management. Modern devices provide different bowl sizes and sensor-directed programs to optimally adjust to varying clinical situations. STUDY DESIGN AND METHODS In an experimental performance study, the discontinuous autotransfusion device XTRA (LivaNova/Sorin) was evaluated using fresh donor blood anticoagulated with heparin 5 U/mL and adjusted to a hematocrit of 10% or 25%, representing orthopedic or cardiac surgery. Test blood was processed with the autotransfusion device XTRA in four different bowls (55 mL, 125 mL, 175 mL, and 225 mL) and in three different program modes (a standard program, an optimized program, and an emergency program). RESULTS Processing speed increased with bowl size and with the emergency program (range, 6.4-29.8 mL red blood cells [RBCs]/min). The RBC recovery rate exceeded 90% for all bowls and programs except the 55-mL bowl with the emergency program. Plasma elimination exceeded 95% for all bowls and programs except the 225-mL bowl with the emergency and standard programs. Maximal RBC recovery (range, 94.7%-97.6%) and plasma elimination (range, 98.7%-99.5%) were obtained with the medium-sized bowls (125 mL and 175 mL) and the optimized program. Elimination rates for potassium or plasma free hemoglobin were consistently lower than for protein or albumin and were highest for heparin. CONCLUSIONS Increased hematocrit and RBC recovery rates are obtained with the optimized program Popt with the discontinuous autotransfusion device. The emergency program Pem speeds up the process but leads to RBC loss and reduced plasma elimination rates; therefore, it should be restricted to emergency situations. All four different sized bowls have high performance. Plasma elimination is represented best by protein or albumin elimination rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the Sorin Xtra® autotransfusion system

The performance of the Sorin Xtra® Autotransfusion System (ATS) was studied in 62 patients undergoing coronary artery bypass grafting. Blood was collected intraoperatively and washed using three different wash sets in 4 groups. Both collected and washed blood were analysed for hemoglobin levels and hematocrit, concentrations of proteins, albumin, heparin and plasma free hemoglobin (PFH) were de...

متن کامل

Effect of partial-filling autotransfusion bowls on the quality of reinfused product.

Intraoperative autotransfusion is used in a variety of surgical procedures with the quantity of blood loss dependent upon numerous factors. These procedures may or may not produce a full autotransfusion bowl. The inadequate removal of contaminants has been correlated to the incomplete filling of bowls, resulting in a condition called "Salvaged Blood Syndrome." The purpose of this study was to a...

متن کامل

Quality of processed blood for autotransfusion.

Centrifugal red blood cell washers for intraoperative autotransfusion process shed blood during surgery. In this study, the quality of processed fresh, human bank blood was assessed in a standardized laboratory setting during standard, medium, and high flow processing. Red cell recovery rates and plasma washout efficiencies were compared using three different devices. The accurate parameters me...

متن کامل

Introduction of a Greenhouse as an Alternative Housing System to a Conventional House and Its Impact on Broiler Performance and Blood and Carcass Variables

A study was conducted to compare the growth performance as well as blood and carcass variables of two broiler strains reared in a conventional broiler house and a modified greenhouse equipped with cooling pads and tunnel ventilation system. Eight hundred day-old chickens of two commercial strains (Ross  308 and Lohmann) were selected and placed in  8 floor pens (4 pens of  50 broilers for each ...

متن کامل

Effects of Six Weeks Combined Training Program on Hematological Parameters in Elite Basketball Players

Background. In team sports, according to perform variety of motor skills, development of special bio-motor abilities and imposed proper exercise stress, hematologic adaptations following exercise will be different. Objectives. Therefore, the aim of this study was the effects of six weeks combined training program on hematological parameters in elite basketball players. Methods. Fifteen athl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transfusion

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2017