Determination and validation of duloxetine hydrochloride in capsules by HPLC with pre-column derivatization and fluorescence detection.
نویسنده
چکیده
A high-performance liquid chromatographic (HPLC) method is described for the determination of duloxetine hydrochloride in capsules. The method was based on pre-column derivatization with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole using the fluorimetric detection technique. Duloxetine hydrochloride was analyzed by HPLC using an Inertsil C18 column (5 μm, 150 × 4.6 mm) and mobile phase consisted of methanol and water (65:35, v/v). The fluorescence detector was adjusted at excitation and emission wavelengths of 461 and 521 nm, respectively. The linearity of the method was in the range of 10-600 ng/mL. Limits of detection and quantification were 0.51 and 1.53 ng/mL, respectively. The proposed method was successfully applied for determination of duloxetine hydrochloride in its pharmaceutical preparation. The results were in good agreement with those obtained using a reference method.
منابع مشابه
High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
متن کاملDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
متن کاملStereospecific Determination of Mefloquine in Whole Blood by HPLC
Mefloquine, as a racemic mixture, is used for the treatment and prophylaxis of malaria. Stereoselective pharmacodynamic and pharmacokinetic differences has been observed for mefloquine. In this study a modified stereoselective HPLC method is presented for determination of mefloquine (MFQ) enantiomers in whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatographic science
دوره 50 6 شماره
صفحات -
تاریخ انتشار 2012