Impact of neonate haematocrit variability on the longitudinal relaxation time of blood: Implications for arterial spin labelling MRI
نویسندگان
چکیده
BACKGROUND AND PURPOSE The longitudinal relaxation time of blood (T 1b) is influenced by haematocrit (Hct) which is known to vary in neonates. The purpose of this study was threefold: to obtain T 1b values in neonates, to investigate how the T 1b influences quantitative arterial spin labelling (ASL), and to evaluate if known relationships between T 1b and haematocrit (Hct) hold true when Hct is measured by means of a point-of-care device. MATERIALS AND METHODS One hundred and four neonates with 120 MR scan sessions (3 T) were included. The T 1b was obtained from a T 1 inversion recovery sequence. T 1b-induced changes in ASL cerebral blood flow estimates were evaluated. The Hct was obtained by means of a point-of-care device. Linear regression analysis was used to investigate the relation between Hct and MRI-derived R1 of blood (the inverse of the T 1b). RESULTS Mean T 1b was 1.85 s (sd 0.2 s). The mean T 1b in preterm neonates was 1.77 s, 1.89 s in preterm neonates scanned at term-equivalent age (TEA) and 1.81 s in diseased neonates. The T 1b in the TEA was significantly different from the T 1b in the preterm (p < 0.05). The change in perfusion induced by the T 1b was -11% (sd 9.1%, p < 0.001). The relation between arterial-drawn Hct and R1b was R1b = 0.80 × Hct + 0.22, which falls within the confidence interval of the previously established relationships, whereas capillary-drawn Hct did not correlate with R1b. CONCLUSION We demonstrated a wide variability of the T 1b in neonates and the implications it could have in methods relying on the actual T 1b as for instance ASL. It was concluded that arterial-drawn Hct values obtained from a point-of-care device can be used to infer the T 1b whereas our data did not support the use of capillary-drawn Hct for T 1b correction.
منابع مشابه
Perfusion measurements by dynamic susceptibility MRI
List of Papers This thesis is based on the following papers, which are referred to in the text by their Roman numerals. Abbreviations ADC Apparent diffusion coefficient AIF Arterial input function ASL Arterial spin labeling CBF Cerebral blood flow CBV Cerebral blood volume CPB Cardio pulmonary bypass DSC-MRI Dynamic susceptibility contrast MRI MRI Magnetic resonance imaging MRS Magnetic resonan...
متن کاملRelevance between MRI longitudinal relaxation rate and gadolinium concentration in Gd3+/GO/alginate nanocomposite
Objective(s): Relevance between magnetic resonance imaging (MRI) relaxation rate and concentration of magnetic nanoparticles determines the capability of a nanomaterial to provide MRI contrast. In the present study, alginate was conjugated to gadolinium/graphene oxide nanocomposite to form gadolinium/graphene oxide/alginate nanocomposite, aiming to investigate its effect on the relevance betwee...
متن کاملCharacterizing the origin of the arterial spin labelling signal in MRI using a multiecho acquisition approach.
Arterial spin labelling (ASL) can noninvasively isolate the MR signal from arterial blood water that has flowed into the brain. In gray matter, the labelled bolus is dispersed within three main compartments during image acquisition: the intravascular compartment; intracellular tissue space; and the extracellular tissue space. Changes in the relative volumes of the extracellular and intracellula...
متن کاملProton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
To further investigate the dependency of fMRI signal changes on echo time TE, we measured T2 and T2* values, obtained from human blood samples at various oxygenation levels and used them in a simple model to calculated signal enhancement in fMRI. In addition, the longitudinal relaxation time T1 of human blood was determined for reference. All measurements were performed at 23 degrees C to reduc...
متن کاملA general model to calculate the spin-lattice (T1) relaxation time of blood, accounting for haematocrit, oxygen saturation and magnetic field strength.
Many MRI techniques require prior knowledge of the T1-relaxation time of blood (T1bl). An assumed/fixed value is often used; however, T1bl is sensitive to magnetic field (B0), haematocrit (Hct), and oxygen saturation (Y). We aimed to combine data from previous in vitro measurements into a mathematical model, to estimate T1bl as a function of B0, Hct, and Y. The model was shown to predict T1bl f...
متن کامل