Measurement and Analysis of In-vessel Component Activation and Gamma Dose Rate Distribution in Joyo
نویسندگان
چکیده
The in-vessel gamma dose rate was measured in the experimental fast reactor Joyo to evaluate the activation of reactor structural components and the radiation exposure of the fiber scope used for in-vessel visual inspection. The measurement system, which requires a wide sensitivity range and high durability in a high-temperature environment, was specifically developed for use in the sodium cooled fast reactor. The gamma-ray detector was calibrated by simulating the actual temperature conditions in Joyo. Using this system, the in-vessel gamma dose rate with cooling times of 450 and 720 days after reactor shutdown was measured in Joyo, which has been operated for 71,000 hours over approximately 30 years. The gamma dose rate was calculated using QAD-CGGP2 code with the gamma source intensity obtained by the ORIGEN2 code. The neutron flux used as input to the ORIGEN2 was evaluated by the Joyo dosimetry method. The ratio between the calculated and experimental values ranged from 1.1 to 2.4, confirming the accuracy of gamma dose rate and component activation calculation.
منابع مشابه
Shielding studies on a total-body neutron activation facility
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملGamma Dose Rate Measurement and Dose Rate Calculation for Sensitive Organs in the Vicinity of Hot Springs in Kerman Province
Introduction: All of the people worldwide are exposed to low levels of radiation. Cancer induction and genetic disorders are among the hazards of low level exposure. In some cases, radiation close to hot springs is higher than normal areas due to a high concentration and the decay products of Ra-226. Given the use of hot springs by the general public because of their therapeutic p...
متن کاملMeasurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces. Materials and Methods: Using an ionization chamber detector, the outdoor and indoor ambient gamma d...
متن کاملGamma Radiation Measurement due to Natural Radioactivity in Hot Water Spring of Behbahan
Introduction: Many people use hot water springs to treat some diseases, such as rheumatism, arthritis, and skin diseases, but they are unaware of the presence of natural radioactive substances that may be found in hot water springs. An effective way to understand the radiation risk of these elements are measuring the dose rate of radiation. In this study, for the first time, ga...
متن کاملEstimation of neutron and gamma dose in the MNSR research reactor
In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...
متن کامل