Quantitative versus qualitative analysis of peak expiratory flow in occupational asthma.
نویسندگان
چکیده
BACKGROUND Peak expiratory flow rates (PEF) are often used to confirm the diagnosis of occupational asthma. The records are usually analysed qualitatively, and this may lead to interobserver disagreement. In this study the diagnostic value of a qualitative assessment of change in PEF was compared with objective measures of change in PEF and the results of a specific inhalation challenge test with plicatic acid. METHODS Twenty five patients with possible red cedar asthma recorded PEF six times a day for three weeks at work and for two weeks away from work and underwent a challenge test with plicatic acid at the end of the recording period. Patients were considered to have cedar asthma if the FEV1 after inhalation of plicatic acid was 15% or more below that on the control day. PEF was plotted against time and assessed qualitatively by three physicians. The graph was considered positive for cedar asthma if two of the three physicians agreed that PEF was lower at work than away from work. The 95% confidence interval for variation in PEF between periods at work and away from work was also obtained from 15 asthmatic patients without occupational asthma. Differences in PEF between periods at work and away from work were considered positive for occupational asthma in the patients exposed to cedar when they were outside the 95% confidence interval for variations in PEF in the 15 patients whose asthma was nonoccupational. RESULTS Of the 25 men studied, 15 had a positive response to plicatic acid. The qualitative PEF analysis had a sensitivity of 87% and a specificity of 90% in confirming red cedar asthma as diagnosed by the specific challenge test. Among the objective methods tested, only the difference in mean PEF between the maximum PEF at weekends and the minimum PEF on working days had a sensitivity (93%) greater than that of the qualitative method and a similar specificity. CONCLUSIONS The qualitative assessment of PEF is a good diagnostic test for cedar asthma. Only one objective method of PEF analysis proved to be slightly more sensitive than the qualitative method and similar in specificity.
منابع مشابه
Peak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملبررسی تاثیر 1،6 هگزامتیلن دی ایزوسیا نات بر نتایج تست پیک فلومتری در کارگران کارگاههای رنگ کاری اتومبیل شهر اصفهان
Abstract Background & Aims: Hexamethylene diisocyanate is an aliphatic isocyanate and car painters are exposed to it. One of the most important disorders is occupational asthma. The aim of this study was to survey the effect of 1, 6 hexamethylene diisocyanate on the peak expiratory flow test to car painters in Isfahan. Materials & Methods: In this descriptive and a cross-sectional study the f...
متن کاملDevelopment of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma
If asthma is due to work exposures there must be a relation between these exposures and the asthma. Asthma causes airway hyperresponsiveness and obstruction; the obstruction can be measured with portable meters, which usually measure peak expiratory flow, or sometimes forced expiratory volume in 1 second (FEV1). These can be measured serially (for instance 2 hourly) over several weeks at and aw...
متن کاملEffect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma.
Serial peak expiratory flow records are recommended in the first-line investigation of suspected occupational asthma. The effects of sequentially reducing the numbers of working weeks, consecutive days at work and readings taken per day on diagnostic sensitivity and specificity were investigated, using good quality peak expiratory flow records from 81 workers with independently confirmed occupa...
متن کاملA Systematic Review of Serial Peak Expiratory Flow Measurements in the Diagnosis of Occupational Asthma
This paper systematically reviews literature on the application of serial peak expiratory flow (PEF) measurements in the diagnosis of occupational asthma and calculates summary estimates of the sensitivity, specificity, and feasibility of serial PEFs.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 48 1 شماره
صفحات -
تاریخ انتشار 1993