Improved quantitative myocardial T2 mapping: Impact of the fitting model.
نویسندگان
چکیده
PURPOSE To develop an improved T2 prepared (T2 prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T2 mapping. METHODS Myocardial T2 mapping is commonly performed by acquisition of multiple T2 prep bSSFP images and estimating the voxel-wise T2 values using a two-parameter fit for relaxation. However, a two-parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T2 prep RF pulses, which may decrease the robustness of T2 mapping. Therefore, we propose a novel T2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T2 prep echo time. This enables the robust estimation of T2 maps using a 3-parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T2 maps generated using the proposed 3-parameter model with the conventional two-parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models. RESULTS Phantom and in vivo data show that the T2 values generated by the proposed 3-parameter model fitting do not change with different choices of the T2 prep echo times, and are not statistically different than the reference values for the phantom (P = 0.10 with three T2 prep echoes). The two-parameter model exhibits dependence on the choice of T2 prep echo times and are significantly different than the reference values (P = 0.01 with three T2 prep echoes). CONCLUSION The proposed imaging sequence in combination with a three-parameter model allows accurate measurement of myocardial T2 values, which is independent of number and duration of T2 prep echo times. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
منابع مشابه
Precision and reproducibility of T2 quantifications in myocardial T2 mapping: impact of the number of echoes and reconstruction model
Background Quantitative myocardial T2 is a promising technique to assess myocardial inflammation and edema (1). Recent implementations have utilized T2-prepared (T2prep) SSFP sequences to acquire a multiple T2 weighted images at different echo times, and generate T2 maps based on a 2-parameter (2P-fit) model of T2 decay (2,3). Recently, a 3-parameter fitting (3P-fit) model was found superior to...
متن کاملMotion correction for free breathing quantitative myocardial t2 mapping: impact on reproducibility and spatial variability
Background Quantitative myocardial T2 mapping is a promising technique for in-vivo assessment of inflammation and edema [1]. Free breathing T2 mapping sequences increase the flexibility in the choice of the number of T2prep echoes times (TET2P), but should be combined with respiratory motion correction technique [2]. In this study, we sought to evaluate the performance of the Adaptive Registrat...
متن کاملImpact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
BACKGROUND To evaluate and quantify the impact of a novel image-based motion correction technique in myocardial T2 mapping in terms of measurement reproducibility and spatial variability. METHODS Twelve healthy adult subjects were imaged using breath-hold (BH), free breathing (FB), and free breathing with respiratory navigator gating (FB + NAV) myocardial T2 mapping sequences. Fifty patients ...
متن کاملImproved detection of myocardial involvement in acute inflammatory cardiomyopathies using T2 mapping.
BACKGROUND T2-weighted cardiac magnetic resonance imaging is useful in diagnosing acute inflammatory myocardial diseases, such as myocarditis and tako-tsubo cardiomyopathy (TTCM). We hypothesized that quantitative T2 mapping could better delineate myocardial involvement in these disorders versus T2-weighted imaging. METHODS AND RESULTS Thirty patients with suspected myocarditis or TTCM, refer...
متن کاملT2 relaxation time mapping in phantom and in vivo myocardial studies to investigate optimal method of quantification
Reproducible and accurate T2 measurements are required for the characterization of myocardial tissue, e. g. to distinguish healthy, scar and edematous myocardium. It is the objective of this study to investigate the impact of the fitting algorithm applied for the T2 quantification from data derived from a single-breathhold T2-prepared steady-state free precession (T2p-SSFP) imaging technique.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره شماره
صفحات -
تاریخ انتشار 2014