The variance-covariance method: microdosimetry in time-varying low dose-rate radiation fields.
نویسندگان
چکیده
The variance-covariance method is employed at low doses and in radiation fields of low dose rates from an 241Am (4 nGy/s) and a 90Sr (300 nGy/s) source. The preliminary applications and results illustrate some of the potential of the method, and show that the dose average of lineal energy or energy imparted can be determined over a wide range of doses and dose rates. The dose averages obtained with the variance-covariance method in time-varying fields, for which the conventional variance method is not suitable, agree well with results obtained under the condition of constant dose rate. The results are compared to data obtained in terms of the conventional single-event measurements. The method has evident advantages, such as facility and speed of measurement.
منابع مشابه
Microdosimetry: experimental methods and medical applications
Introduction: Microdosimetry is a fundamental method that studies the nature of energy transfer in micron volumes in the particular biological cells. In a biological target, the amount of ionization does not indicate the magnitude of biological radiation-induced damage. However, the severity of biological harm depends strongly on the amount of the linear energy transfer along t...
متن کاملMicrodosimetry study of a multicellular model with mono-energetic electrons using Geant4-DNA simulation toolkit
Introduction: The goal of any type of radiation therapy in the treatment of tumors, in addition to destroying cancer cells, is to minimizing radiation to nearby healthy cells and thus reducing side damages. For this purpose, targeted radiation therapy (TRT) is more effective in treating of single cells or small cluster of cells. The main factor in the success of this method is...
متن کاملModelling radiation fields of ion beams in tissue-like materials
Fast nuclei are ionizing radiation which can cause deleterious effects to irradiated cells. The modelling of the interactions of such ions with matter and the related effects are very important to physics, radiobiology, medicine and space science and technology. A powerful method to study the interactions of ionizing radiation with biological systems was developed in the field of microdosimetry...
متن کاملPerformance of Sife - Eldeen dosimeter over broad absorbed dose and dose rate ranges of γ – radiation and at different temperatures
Background: Results are presented on some dosimetric characteristics of Sife – Eldeen dosimeter based on the radiation induced conductivity (RIC) of 3.5 M aqueous urea solutions. The studied characteristics were the response (RIC) of Sife – Eldeen dosimeter in broad ranges of absorbed dose, dose rates and at different irradiation temperature. Materials and Methods: Kent EIL5007 conductivity met...
متن کاملApplication of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom
Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation and environmental biophysics
دوره 27 4 شماره
صفحات -
تاریخ انتشار 1988