Measuring Physical Activity in Free-Living Conditions—Comparison of Three Accelerometry-Based Methods
نویسندگان
چکیده
We examined the agreement in time spent on different physical activity (PA) levels using (1) mean amplitude deviation (MAD) of raw acceleration from the hip, (2) wrist-worn Polar Active, and (3) hip-worn Actigraph counts using Freedson's cut-points among adults under free-living conditions. PA was measured in 41 volunteers (mean age 47.6 years) for 14 days. Two MET-based threshold sets were used for MAD and Polar Active for sedentary time (ST) and time spent in light (LPA), moderate (MPA), and vigorous (VPA) PA. Actigraph counts were divided into PA classes, ≤100 counts/min for ST and Freedson's cut-points for LPA, MPA, and VPA. Analysis criteria were simultaneous use of devices for at least 4 days of >500 min/d. The between-method differences were analyzed using a repeated measures analysis of variance test. Bland-Altman plots and ROC graphs were also employed. Valid data were available from 27 participants. Polar Active produced the highest amount of VPA with both thresholds (≥5 and ≥6 MET; mean difference 17.9-30.9 min/d, P < 0.001). With the threshold 3-6 MET for MPA, Polar Active indicated 19.2 min/d more than MAD (95% CI 5.8-32.6) and 51.0 min/d more than Actigraph (95% CI 36.7-65.2). The results did not differ with 3.5-5 MET for MPA [F(1.44, 37.43) = 1.92, P = 0.170]. MAD and Actigraph were closest to each other for ST with the threshold < 1.5 MET (mean difference 22.2 min/d, 95% CI 7.1-37.3). With the threshold <2 MET, Polar Active and Actigraph provided similar results (mean difference 7.0 min/d, 95% CI -17.8-31.7). Moderate to high agreement (area under the ROC curve 0.806-0.963) was found between the methods for the fulfillment of the recommendation for daily moderate-to-vigorous PA of 60 min. In free-living conditions the agreement between MAD, Polar Active, and Actigraph for measuring time spent on different activity levels in adults was dependent on the activity thresholds used and PA intensity. ROC analyses showed moderate to high agreement for the fulfillment of the recommendation for daily MVPA. Without additional statistical adjustment, these methods cannot be used interchangeably when measuring daily PA, but any of the methods can be used to identify persons with insufficient daily amount of MVPA.
منابع مشابه
Evaluations of Actiheart, IDEEA® and RT3 monitors for estimating activity energy expenditure in free-living women
Activity energy expenditure (AEE) during free-living conditions can be assessed using devices based on different principles. To make proper comparisons of different devices' capacities to assess AEE, they should be evaluated in the same population. Thus, in the present study we evaluated, in the same group of subjects, the ability of three devices to assess AEE in groups and individuals during ...
متن کاملAssessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors
Wearable physical activity monitors are growing in popularity and provide the opportunity for large numbers of the public to self-monitor physical activity behaviours. The latest generation of these devices feature multiple sensors, ostensibly similar or even superior to advanced research instruments. However, little is known about the accuracy of their energy expenditure estimates. Here, we as...
متن کاملDevelopment of a wearable motion detector for telemonitoring and real-time identification of physical activity.
Characteristics of physical activity are indicative of one's mobility level, latent chronic diseases, and aging process. Current research has been oriented to provide quantitative assessment of physical activity with ambulatory monitoring approaches. This study presents the design of a portable microprocessor-based accelerometry measuring device to implement real-time physical activity identifi...
متن کاملComparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study
BACKGROUND Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices, it is of interest to know whether the different devices give similar information about PA levels a...
متن کاملConvergent validity of six methods to assess physical activity in daily life.
The purpose was to examine the agreement (convergent validity) between six common measures of habitual physical activity to estimate durations of light, moderate, vigorous, and total activity in a range of free-living individuals. Over 7 consecutive days, 49 ethnic Chinese (30 men, 19 women), aged 15-55 yr, wore a Polar heart rate monitor, a uniaxial MTI, and triaxial Tritrac accelerometer, plu...