Continuous noninvasive in vivo monitoring of intravascular plasma volume and hematocrit changes during hemodialysis in humans: direct comparison with the CRIT-LINE

نویسندگان

  • Bin Deng
  • Evan Kastner
  • Sriram S. Narsipur
  • Jerry Goodisman
  • J. Chaiken
چکیده

We report a new device and algorithm that allows simultaneous monitoring of the hematocrit and plasma volume fraction of blood within the intravascular space of an optically probed volume of skin. Skin is probed with a near infrared (NIR) laser and simultaneously collecting the Rayleigh and Mie scattered light as one raw signal and the undifferentiated Raman and fluorescence emission as the second raw signal. These signals are combined using six parameters that can be obtained by either direct calculation or empirical calibration to permit monitoring of the blood in human skin (e.g. fingertips). We tested a device based on the algorithm that might be useful in allowing the early detection of blood loss for people who have no external injury but may be hemorrhaging internally. IRB allowed experiments monitoring blood in human fingertip skin in vivo during routine hemodialysis demonstrated good agreement between the experimental device and the CRIT-LINE, an FDA approved device that is built into the dialysis machine and applies the Twersky algorithm to blood in the dialysis machine (i.e. in vitro). Based on observation of 9 different test subjects, as dialysis removes fluid from the intravascular space causing an increase in hematocrit and a decrease in plasma volume, the CRIT-LINE response is closely emulated (typical per session linear correlation r=0.78, N=87, p<0.0001) with the new device. Calibration across subjects, the measurement of absolute hematocrit, and potential confounding factors will also be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Intradialytic blood volume monitoring in ambulatory hemodialysis patients: a randomized trial.

Complications related to inadequate volume management are common during hemodialysis. This trial tested the hypothesis that availability of an intradialytic blood volume monitoring (IBVM) device improves fluid removal, reducing morbidity. A six-center, randomized trial with 6 mo of intervention comparing IBVM using Crit-Line versus conventional clinical monitoring was conducted. The average rat...

متن کامل

بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی

Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...

متن کامل

Continuous haematocrit monitoring during intradialytic hypotension: precipitous decline in plasma refill rates.

BACKGROUND Intradialytic hypotension (IDH) during ultrafiltration remains a major source of haemodialysis related morbidity, despite technological advances including continuous haematocrit monitoring and automated blood volume controlled dialysis machines. We hypothesized that studying the relationship between ultrafiltration rate and plasma refill rate (UFR, PRR) before and during IDH would pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014