Biomechanical analysis of limited-contact plate used for osteosynthesis.
نویسندگان
چکیده
This paper presents the results of numerical analysis aimed at determining the state of stresses and displacements of compression plate used in osteosynthesis of tibia, carried out by applying finite element method using the ANSYS program. The analysis took into account two variants of the osteosynthesis. Variant I included the osteosynthesis in which plate was attached directly to the bone, in variant II, the plate was moved away from the bones by about 5 mm. Biomechanical characteristics of the corrective osteotomy plate-tibia was determined for implants made of Ti-6Al-4V alloy. The boundary conditions adopted for the analysis reflect phenomena occurring in a real system. Based on the results of the analysis relative displacements and reduced stresses in various components were determined as a function of the applied load within the range of F = 500-1500 N. The maximum forces, both variant I and variant II determined during analysis, ensure that the generated stress does not exceed yield strength of the material and compressive strength of the bone, and do not exceed safety movement in the fracture gap. In addition, it was found that the locking of the compressive plate to the bone has a little effect on the distribution of displacements and stresses on the plate-tibia system in the case of a simple fracture.
منابع مشابه
Minimally Invasive Plate Osteosynthesis (MIPO) in Long Bone Fractures – Biomechanics – Design – Clinical Results
Complex periarticular fractures of the long bones are difficult to treat. Classic intramedullary osteosynthesis do not provide a stable fixation (Wiss et al., 1986), while open reduction and rigid fixation by classic plates (recommended in the 60s-70s) is requiring large incisions with important deperiostation. Potential complications as infections, consolidation delays and construct damage due...
متن کاملFixation of Supracondylar Femoral Fractures: a Biomechanical Analysis Comparing 95° Blade Plates and Dynamic Condylar Screws (dcs)
OBJECTIVE To determine, by means of comparative biomechanical tests, whether greater compressive load resistance and flexion is presented by 95° angled blade plates or by dynamic condylar screws (DCS), and to correlate the failure type presented during the tests with each type of plate. METHODS Sixty-five porcine femurs were subjected to 1 cm medial wedge osteotomy, in the metaphysis, to simu...
متن کاملExpandable intramedullary nail: review of biomechanical studies
This article reviews studies of Fixion expandable nail biomechanical properties in case of long bones fractures osteosynthesis. The purpose of this study was to systematize biomechanical researches dedicated to the expandable nail. There were found seven biomechanical studies published between 2005 and 2008. Among them, six studies are devoted to mechanical experiments, and one is a comment to ...
متن کاملZásady a klinické použití uzamykatelné kompresní dlahy LCP
The principle of the locking compression plate (LCP) is represented by the combination of two completely different anchorage technologies and two opposed principles of osteosynthesis in one implant it combines the principles of conventional plate osteosynthesis for direct anatomical reduction with those of bridging plate osteosynthesis. Since the LCP can be used as a conventional plate using on...
متن کاملComparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate
Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta of bioengineering and biomechanics
دوره 16 1 شماره
صفحات -
تاریخ انتشار 2014