Hip fracture discrimination study: QUS of the radius and the calcaneum.
نویسندگان
چکیده
As an emerging alternative to current radiation-based bone densitometry techniques, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the noninvasive assessment of fracture risk in the management of osteoporosis. However, there are also a multiplicity of technologically different QUS devices available on the market and, so far, no study has compared heel and radius QUS device for the discrimination of subjects with hip fractures. Our study evaluated the ability of three QUS devices (one calcaneal gel-coupled system, one calcaneal water-coupled system, and one radius system) to discriminate osteoporotic from controls subjects, using the same population. We also checked if the combination of two different skeletal sites (i.e., calcaneum and radius) improve the discriminatory ability of the QUS devices. Forty-five women aged 79.1+/-7.1 yr with hip fractures within the last 4 d were used as the hip-fracture group and compared to 40 healthy controls from 65-87 yr. In addition, 47 young controls, aged 20-40 yr, were used as reference population to express some of the results as T-scores. QUS measurements were performed with the Hologic Sahara, Ge-Lunar Achilles+, and Sunlight Omnisense devices according to the manufacturer's recommendations. Adjusted odds ratio results showed that a decrease in Omnisense SOS of 1 standard deviation (SD) was associated with a significant increase in fracture risk (OR adj.=2.83) comparable with Sahara BUA (OR adj.=2.42) and Achilles BUA (OR adj.=3.29). However, given the large overlap between the 95% intervals of each odds ratio, no significant difference was found between the devices. Similarly, comparison between the areas under ROC curves did not show any significant difference between all the parameters. Considering the parameters provided per default by each QUS device, the Sahara, Achilles, and Omnisense devices classified correctly 70, 67.5, and 62.5% of the subjects, respectively. Although the OR of the combination of radius and calcaneum is improved (3.62 to 4.74) compared with either one of the single skeletal site, the large confidence intervals do not allow to claim a significant difference. The three QUS technologies tested against hip fractures seem to show the same discriminatory ability. However, there is some differences in the definition of the diagnostic threshold underlying the nonusability of the World Health Organization (WHO) osteoporosis definition. Finally the combination of several site using two different devices is not clinically relevant. Potential interest could be seen in combining several sites using the same device, supposing that such device would measure differently active bone.
منابع مشابه
Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?
There is a growing interest in the use of quantitative ultrasound (QUS) measurements as an alternative to current radiation-based bone densitometry techniques for the noninvasive assessment of fracture risk. While most of the commercialized ultrasound devices measure only single predefined peripheral skeletal sites, the Omnisense prototype (Sunlight Ltd., Israel) can be used on multiple bones, ...
متن کاملLower Bone Mineral Density is Associated with Intertrochanteric Hip Fracture
Background: A better understanding of how bone mineral density and vitamin D levels are associated with femoralneck and intertrochanteric hip fractures may help inform healthcare providers. We asked: 1) In patients age ≥ 55 years,is there a difference in quantitative ultrasound of the heel (QUS) t-score between patients with fractures of the femoralneck and those with fractures of the intertroc...
متن کاملRelationship between Bone Mineral Density and Serum Vitamin D with Low Energy Hip and Distal Radius Fractures: A Case-Control Study
Background: The main purpose of this study was to determine the relationship between serum vitamin D and the status of bone mineral density in patients with low-energy hip and distal radius fracture. Methods: This retrospective case-control study was performed between January 2013 and January 2014. Participants aged 55 years or older were divided to case group including 85 patients with lo...
متن کاملEconomic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture
Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...
متن کاملUltrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device.
RATIONALE AND OBJECTIVES To assess a new multisite quantitative ultrasound (QUS) device (Sunlight Omnisense 7000 S) suitable for the measurement of speed of sound (SOS) in the phalanges, radius, and tibia. METHODS The study group consisted of 270 healthy Caucasian postmenopausal patients (mean age: 60.0 +/- 7.6 years) and 53 Caucasian postmenopausal patients (mean age: 67.2 +/- 7.4 years) wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry
دوره 6 2 شماره
صفحات -
تاریخ انتشار 2003