Biomechanical comparison using finite element analysis of different screw configurations in the fixation of femoral neck fractures

نویسندگان

  • K. Gok
  • S. Inal
چکیده

In this research, biomechanical behaviors of five different configurations of screws used for stabilization of femoral neck fracture under axial loading have been examined, and which configuration is best has been investigated. A point cloud was obtained after scanning the human femoral model with a three dimensional (3-D) scanner, and this point cloud was converted to a 3-D femoral model by Geomagic Studio software. Femoral neck fracture was modeled by SolidWorks software for five different configurations: dual parallel, triple parallel, triangle, inverted triangle and square, and computer-aided numerical analysis of different configurations were carried out by ANSYS Workbench finite element analysis (FEA) software. For each configuration, mesh process, loading status (axial), boundary conditions and material model were applied in finite element analysis software. Von Mises stress values in the upper and lower proximity of the femur and screws were calculated. According to FEA results, it was particularly advantageous to use the fixation type of triangle configuration. The lowest values are found as 223.32 MPa at the lower, 63.34 MPa at the upper proximity and 493.24 MPa at the screws in triangle configuration. This showed that this configuration creates minimum stress at the upper and lower proximity of the fracture line. Clinically, we believe that the lowest stress values which are created by triangle configuration encompass the most advantageous method. In clinical practices, it is believed that using more than three screws does not provide any benefit. Furthermore, the highest stresses are as follows: at upper proximity 394.79 MPa in triple parallel configuration, for lower proximity 651.2 MPa in square configuration and for screw 2459 MPa in inverted triangle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison of dynamic hip screw and Gamma nail for the treatment of unstable trochanteric fractures: a finite element study

Objectives: To investigate the biomechanical behavior of the femur with two different implant configurations, namely dynamic hip screw and Gamma nail, in the treatment of two types of unstable intertrochanteric femoral fracture. Methods: A 3D finite element model of the intact proximal femur was constructed, from which two types of fractured models (AO classification 31-A2 and 31-A3) were produ...

متن کامل

Finite Element Analysis for the Treatment of Proximal Femoral Fracture

Dynamic hip screw and gamma nail have been widely used to treat the patients with proximal femoral fractures, but clinical failures of those implants are still to be found. This study developed three-dimensional finite element models to investigate the biomechanical performances of the implants. Two kinds of commercially available implants (dynamic hip screw and gamma nail) and one newly design...

متن کامل

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

Comparison of Three Fixation Methods for Femoral Neck Fracture in Young Adults: Experimental and Numerical Investigations

Femoral neck fractures in young patients are usually caused by a high-energy trauma, which results in a perpendicular fracture. Although efforts are focused on preserving the femoral head in young patients, vertical femoral neck fracture is a problematic orthopedic injury due to the domination of shear forces. Due to controversy regarding which fixation method is the best choice, the purpose of...

متن کامل

Subtrochanteric fracture: a rare but severe complication after screw fixation of femoral neck fractures in the elderly.

Cannulated screw fixation is a minimal invasive technique to treat undisplaced femoral neck fractures. It is the preferred method in elderly patients who often suffer co-morbidities. There is scarce literature on subtrochanteric femoral fracture as a complication of cannulated screw fixation of a femoral neck fracture. This complication occurred, without an adequate trauma, in two of 35 patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015