Immobilized enzymes in flow-injection analysis: present and trends

نویسندگان

  • J. Ruz
  • F. Lázaro
  • M. D. Luque de Castro
چکیده

An overview of the use of immobilized enzymes in flow-injection analysis (FIA) is presented. The joint use of FIA and immobilized enzymes means that analytical procedures are easily automated, analytical costs are reduced and methods are faster. The future possibilities for this combination are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorometric determination of ethanol in liquor samples by flow-injection analysis using an immobilized enzyme-reactor column with packing prepared by coupling alcohol oxidase and peroxidase onto chitosan beads.

A flow-injection system was developed for the determination of ethanol with an immobilized enzyme-reactor column. This system, which consisted of hand-made reactor columns packed with alcohol oxidase and horseradish peroxidase immobilized onto chitosan beads, and a fluorometric detector, was applied to the determination of ethanol in liquor samples. Under the recommended conditions, the ethanol...

متن کامل

Trends in biosensor research and development

Trends in biosensor research and development are described. Micromachining techniques have been applied to construct biosensor systems. Several detection units for flow injection analysis have been fabricated. An electrochemical flow cell was fabricated, and both an enzyme immobilized column and an electrochemical detector were integrated. A chemiluminescence detector was also fabricated. Biose...

متن کامل

Simultaneous determination of choline and acetylcholine based on a trienzyme chemiluminometric biosensor in a single line flow injection system.

A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d., 75 cm)...

متن کامل

A simple flow-injection method for the determination of blood glucose using a Technicon immobilized enzyme coil

The applicability of a single-channel flow-injection system with immobilized enzyme coil (Technicon) and UV detection to the determination of glucose is described. The method was used for a pure glucose solution and for serum. The detection limit was 0.10 mM, the rate of determination was 20-40 per hour and the precision was satisfactory. The system is very simple and practical when many analys...

متن کامل

Continuous-flow assay with immobilized enzymes for determining of inorganic phosphate in serum.

An automated method for the determination of inorganic phosphate based on flow-injection analysis and on the use of immobilized enzymes is reported. The method features a linear range between 0.1 and 20 mumol/L with a CV < 2.1% and 3.4% for the within-run and between-run studies, respectively, and a sampling throughput of 40 h-1. The sensitivity of the method makes a 1:250 dilution of the serum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 10  شماره 

صفحات  -

تاریخ انتشار 1988